CONTROL VALVE PROGRAMMING AND COVER DRAWING MANUAL

OEM Configuration Setup

Step 1CS – Press NEXT and ▼ simultaneously for 3 seconds and release. Then press NEXT and ▼
STEP 1CS
simultaneously for 3 seconds and release. If screen in Step 2CS does not appear in 5 seconds the lock
on the valve is ac�vated. To unlock press ▼, NEXT, ▲, and CLOCK in sequence, then press NEXT
and ▼ simultaneously for 3 seconds and release. Then press NEXT and ▼ simultaneously for 3
seconds and release.
Step 2CS – Use ▲ or ▼ 1.0 for 1" valve, 1.25 for 1.25" valve, 1.5 for 1.5" valve, 2.0 for 2" valve or
STEP 2CS
1.0TWIN for twin valve.
Press NEXT to go to Step 3CS.
Press REGEN to exit OEM cycle sequence.
Step 3CS – When 2.0 is selected, an addi�onal screen will appear. It is used to select which size flow
STEP 3CS
meter is to be used with the valve, 1.5, 2.0 or 3.0.
Press NEXT to go to Step 4CS.
Press REGEN to return to previous step.
ALTERNATE Step 3CS – Fill Units: If set as a so�ener, when Step 2CS is set to 1.5 and FILL is
ALTERNATE
STEP 3CS
part of the Regenera�on Cycle Sequence, FILL UNITS of kg or min can be selected. Press NEXT to
go to Step 4CS. Press REGEN to return to previous step.