Henny Penny CW-216 Technical Manual page 7

Display counter warmer
Hide thumbs Also See for CW-216:
Table of Contents

Advertisement

1-3. TROUBLESHOOTING (Continued)
PROBLEM
A. Water will
not fill
A. Lights will
not turn on
B. Not all lights
turn on
103
CAUSE
WATER SYSTEM
• Faulty float switch
• Faulty water control switch
• Faulty water valve
• Water supply has been shut
off or disconnected
LIGHTING
• Defective fuse
• Faulty light switch
• No neutral supplied in field
wiring
• Loose or defective wiring
• Faulty light bulb
• Faulty light switch
Model CW-216/CW-114
CORRECTION
• Check float switch per Float Switch
Section
• Check water control switch per Water
Control Switch Section
• Check water valve per Water Valve
Section
• Check the water supply
• Check as per Fuse Section
• Check light switch per Light Switch
Section
• Check field wiring to be sure a
true neutral has been connected
• Check wiring and repair and
replace if necessary
• Replace with recommended
bulb per Light Bulb Section
• Check light switch per Light Switch
Section
1-3