2-16. CONTACTOR

2-17. TERMINAL BLOCK

2-12
1. Remove electrical power supplied to the cabinet.
To avoid electrical shock or property damage, move the
power switch to OFF and disconnect main circuit
breaker, or unplug cord at wall receptacle.
2. Remove the control side panel.
3. Remove the electrical wires from the contactor.
4. Remove the five nuts holding the mounting plate to the end
channel.
5. Remove the screws holding the contactor to the mounting plate.
6. Install a new contactor in reverse order.
7. Replace the end panel.
8. Turn on the power at the breaker box.
1. Remove electrical power supplied to the cabinet.
To avoid electrical shock or property damage, move the
power switch to OFF and disconnect main circuit
breaker, or unplug cord at wall receptacle.
2. Remove the control side end panel.
3. Remove all electrical wires from the terminal block.
4. Remove five nuts holding the mounting plate to the end
channel.
5. Remove the screws holding the terminal block in place.
6. Install a new terminal block in reverse order.
Step 5
7. Replace the end panel.
8. Turn on the power at the breaker box.
Model CW-216/CW-114