When in
mode,
CH2) or (-)(MODE) are pressed, but
When in
mode,
and release (+)(CH1/CH2) or (-)(MODE). To enter TEACH mode, press the (SELECT)(TEACH) button and hold for longer than 2
seconds.
To enter
mode, hold
and pressing
four times unlocks the sensor from either lock mode and the sensor displays
Averaging
Use this menu to set the number of measurements that are averaged together for the analog output. Increasing the averaging
improves repeatability, but increases the total response speed. The default is 16. The filter can be set to 1, 2, 4, 8, 16, 32, 64, 128,
256, or 512. Use the table to determine the total response speed.
Table 2: Response Speed (ms)
Base
Measurement Rate
1
0.5 ms
0.5
1.0 ms
1
2.0 ms
3
3.0 ms
5
5.0 ms
10
Note: The Q5X uses a dynamic measurement rate, so these response times are worst-case.
8
displays when the (SELECT)(TEACH) button is pressed. The switch point displays when (+)(CH1/
displays if the buttons are pressed and held.
displays when (-)(MODE) is pressed and held. To access the manual adjust options, briefly press
and press
four times. To enter
2
4
8
1.5
3
7
3
5
11
5
9
20
8
15
30
15
25
45
www.bannerengineering.com - Tel: + 1 888 373 6767
Q5X Laser Triangulation Sensor with Analog Outputs
mode, hold
and press
Filter Setting
16
32
64
13
26
50
20
45
90
40
80
150
55
110
220
85
170
340
Table 3: Lateral Entry Response
Base Measurement Rate
(ms)
0.5
1.0
2.0
3.0
5.0
When lateral entry needs to be considered, the lateral entry
response is added to calculate the total response time.
seven times. Holding
.
128
256
512
100
200
400
160
320
650
300
600
1200
420
840
1680
680
1350
2270
Lateral Entry Response (ms)
3
5
15
25
50
P/N 219603 Rev. A