Channel 2
Top Menu
Output CH2
Teach Selection CH2
Adaptive Tracking CH2 *
Window Size CH2 **
Output Timing Delays CH2
Delay Timer CH2 ***
Available when
set to
Available when
set to
available when
set to
or
Hysteresis CH2
Offset CH2 ****
Exit Setup
6
Figure 11. Sensor Menu Map—Channel 2
Sub Menu
Light Operate
Dark Operate
Two-Point Static Teach
Dynamic Teach
Foreground Suppression
Background Suppression
Dual Mode
on: Adaptive Tracking on
off: Adaptive Tracking off
High-Speed Adaptive Tracking on
Adaptive Tracking menu is available when Teach CH2 is set to Dual Mode
Auto
0.1 to 291 cm
Window Size menu is available when Teach CH2 is set to FGS
off: no delays enabled
on: enable on and/or off delay (set value in Delay Timer menu)
1 Shot, fixed output pulse duration
Total
ms
to
sec range, set Delay Timer value (seconds have decimal)
Menu not present when
(
and
defaults to 0,
dt1 range: 1 ms to 90 s or 10 ms to 90 s, depending on response speed setting
Set to -0.1 to -300 cm
Sensor controls hysteresis dependent on distance value
Set to 0.1 to 300 cm
Hysteresis menu is available when Teach CH2 is set to Two-Point Static,
Dynamic, or BGS
Set Value:
-291 to 291 cm
Offset menu is available when Teach CH2 is set to FGS or BGS
end: exit setup
www.bannerengineering.com - Tel: + 1 888 373 6767
Q5X Laser Triangulation Sensor with Analog Outputs
default setting
=
Menu items only available when
out2 is set to LO or DO
is set to
defaults to 10)
P/N 219603 Rev. A