5 OPERATING PROCEDURES

ATTENTION
In case of damages, the power cord must be replaced
by qualified personnel only in order to prevent any
shock hazard.
1 - Clean and sanitize the unit according to the instructions in
t h i s m a n u a l . S e e c h a p t e r 5 . 3 C L E A N I N G A N D
SANITIZING PROCEDURES.
2 - Fill the bowls with product to the maximum level mark. Do
not overfill.
The exact quantity of product (expressed as liters and
gallons) is shown by marks on the bowl.
3 - In case of products to be diluted with water, pour water into
bowl first, then add correct quantity of product. In case of
natural squashes, it is advisable to strain them, in order to
prevent pulps from obstructing the faucet outlet.
4 - To obtain the best performance and result, use bases
designed to be run in Granita freezers. Such bases have a
sugar content of 34 degrees Baumé corresponding to 64
degrees Brix.
For soft drinks the bases are to be diluted with more water,
on a 1 plus 5/5.5 basis.
In any case follow the syrup manufacturer's instructions for
both Granita and soft drink recipes.
If natural juices (e.g. lemon, orange) as well as sugarless
products (e.g. coffee) are used, dissolve 150 - 200 grams
of sugar per liter.
IMPORTANT
However Granita mix may be done, its Brix (sugar
percent content) must be at least 13.
IMPORTANT
Operate the dispenser with food products only.
5 - Install the covers and check that they are correctly placed
over the bowls. The dispenser must always run with the
covers installed to prevent a possible contamination of the
product.
6 - Set
the
control
switches

5.1 DESCRIPTION OF CONTROLS.

7 - Always leave the dispenser on, as the refrigeration stops
automatically when Granita reaches the proper thickness.
The mixers will continue to turn.
5. 1 DESCRIPTION OF CONTROLS
The dispenser is equipped with a power switch and a light
switch. In addition each bowl is individually operated by a
mixer/refrigeration switch. In fact it is possible to dispense both
soft drinks and Granita.
When a bowl is in Soft Drink mode the beverage temperature
is controlled by the corresponding thermostat.
When a bowl is in Granita mode the mix viscosity is controlled
by the corresponding adjustment screw located in the rear wall
of each container (for temperature and viscosity setting make
reference to chapter 5.2 OPERATION HELPFUL HINTS).
All the switches are located on the faucet side of the dispenser
Ugolini spa
as
shown
in
chapter
in switch panels protected by switch covers (see figure 1).
With reference to figure 3 dispenser controls functions are as
follows:
Power switch (A)
0 position
:
power is turned OFF to all functions.
I position
:
power is turned ON to all functions
and the other switches are enabled.
The fan motor runs.
Light switch (E)
0 position
:
all top cover lights are OFF.
I position
:
all top cover lights are ON, provided
that power switch (A) is set to I.
Mixer/refrigeration switch (B)
I position
:
mixer and refrigeration ON.
SOFT DRINK mode.
0 position
:
OFF.
II position
:
mixer and refrigeration ON.
GRANITA mode.
Thermostat (D)
Turn clockwise
Turn counterclockwise
To operate the unit:
1 - Set the power switch to I position.
2 - Set the mixer/refrigeration switches as follows:
- to the I position to get soft drink.
- to the II position to get Granita.
3 - Set the light switch to I position.
NHT UL AF BL
figure 1
figure 2
: to decrease temperature
: to increase temperature
5

Hide quick links: