CAUTION!
The motor must never be "forcibly cooled" externally with water.
This can lead to damage and does not help especially with
cooling as it is primarily the inside of the motor that is hot.

Motor:

The drive wheel of your Pedelec can be removed from the
bicycle frame at any time, for example, for cleaning purposes or
in case of a puncture. Proceed extremely carefully when
removing and subsequently installing the drive wheel and note,
in particular, the instructions and information of the
manufacturers of the various components attached to the
wheel, especially the brake disc.
NOTE: For clarity reasons the following diagrams only show the
drive motor integrated in the wheel but not the entire drive
wheel.

Removing the drive wheel:

Note or mark the cable routing and the fixing points of the cable
ties before removing the drive wheel. First loosen and remove
all cable ties which are securing the cables [16] coming from the
motor and cables and leads of other components to the bicycle
frame. Then disconnect the plug [15] on the cable of the motor
[16] from the socket [17] on the battery cable. Loosen the two
nuts [18] or the quick-release mechanism with which the wheel
is fixed to the frame so that the entire wheel can be removed
from the frame of your add-on bike.
CAUTION!
• Note or mark the position of the torque support [20]. This
must be re-fitted in exactly the same position as it was before
removal, when you later attach the wheel.
• Never hold or transport the wheel you have removed by the
cable, [16] coming from the motor. There is a risk of the cable
breaking.