Specifications - Sensata Dimensions 12LPC15 Owner's Manual

Dc to ac power inverter/charger pure sine wave output
Hide thumbs Also See for Dimensions 12LPC15:
Table of Contents

Advertisement

Specifications

WARNING: The inverter is intended to recharge batteries. The battery that is connected to this product is
only suitable if it complies with the given battery standard for that battery type and is provided with a battery
management system that will monitor and control the electrical and thermal health of the battery during
charging. When installing this inverter, the battery is to be verified as in compliance with the applicable battery
standard.
All ratings below assume 12.6 VDC nominal voltage, 25°C ambient temperature, and the inverter is mounted in
free air. 12.6 VDC is to be measured at the inverter input terminals. Specifications are subject to change without
notice. For use at ambient temperatures less than -20°C, use the hardwire connections. The GFCI may not properly
operate at temps below -20°C. At temperatures greater than 25°C, the inverter output is de-rated. See the graph in
"Operation" section of the manual.
Input Voltage (VDC)
Nominal Input Voltage (VDC)
DC Surge Voltage (VDC)
Output Voltage (VAC)
Output Frequency (Hz)
Output Waveform
Output Power (Watts Cont.)
Output Current (AAC Cont.)
Input Current (ADC Cont.)
Input Current (ADC Cont.)
Peak Power (Watts)
Peak Output (AAC)
Motor Starting Rating (h.p.)
Inverter Efficiency
Charger Input Voltage (Vrms)
Max Charger Output Current (ADC)
Input Current Bypass (Arms)
DC Input Capacitance
Minimum Req'd Battery A-Hr*
Max A-Hr**
Weight (lbs.)
Dimensions in. (L x W x H)
Operating Temperature***
Agency Listings
* For optimal charging, the amp hour setting should match the amp hour rating of the connected battery.
** Each inverter amp-hr setting can be adjusted with RV-C CAN or the NVM Setup Utility.
*** At ambient temperatures above 50°C, the inverter/charger may fail to restart in the event it shuts down in an
over temperature condition.
Page 6
THD
Table 1 Specifications
12LPC15 Manual
10.5 – 15.0
12.6
Up to 24
120 +/- 5%
60 +/- .05%
< 5% at 12.6 VDC and 1500W
Pure Sine < 5% THD
1500
12.5
Up to 167 at 12.6 VDC
Up to 190 at 10.5 VDC
3000
25.0
1/2
Up to 80%
85 – 135
65 at 12.6 VDC
20
up to 40,000µF
200
400
30
19.0" x 9.75" x 4.8"
-40°C to 50°C (-40°F to 122°F)
UL458, E100666

Advertisement

Table of Contents
loading

This manual is also suitable for:

Dimensions 12lpc15hrDimensions 12lpc15r

Table of Contents