External Power Mode Continued
Battery Charger Continued
Battery Type
Charger Warm Battery: output switches to
compensated float from bulk/accept/off (hot)
Charger High Battery Temp: output to off
Charger resumes in previous mode: bulk/
accept/float
Charger Low Battery Temp Off: output to off
Enter 0.1C charge rate from Charger Low
Temp Off
Enter 0.1C charge rate from bulk/accept/float
Charger 0.1C charge rate recovery to bulk/
accept/float mode
*Profile value +15°C when charge cycle starts cold plus elapsed minimum time in mode.
Battery Temperature
Table 4 Continued Battery Charger Recipes with BTS
12LPC15 Manual
AGM
Gel
>50°C/ 122°F
<60°C/140°F
>60°C/140°F
<45°C/112°F
N/A
N/A
N/A
N/A
Wet
LFP
N/A
See Profile
Profile value
-5°C
See Profile
Chg Low
Temp Off
value +5°C
See Profile
See profile
value +5°C*