Sensata Dimensions 12LPC15 Owner's Manual page 20

Dc to ac power inverter/charger pure sine wave output
Hide thumbs Also See for Dimensions 12LPC15:
Table of Contents

Advertisement

External Power Mode Continued
Battery Charger Continued
Battery Type
Current Limit
Phase Terminates
Accept charge voltage
@ 77°F/25°C
Accept voltage temp compensated
Maximum accept charge at low
temps
Phase Terminates
Phase Timeout
Float voltage @77°F/25°C
Float voltage temp comp
Phase Timeout
Condition voltage @77°F/25°C
Condition voltage temp
compensation
Condition duration
Condition frequency
Page 20
AGM
Bulk Charge Phase
1. When battery voltage reaches the accept voltage
2. Bulk charge will extend when load management
reduces charger current below 50% (25 A)
Accept Charge Phase
14.3 VDC
15.0 VDC @ 4 °C
1. When charge current is reduced.
2. When the accept timeout is reached.
3. If the charger can't maintain the accept voltage
6 hours (may be configured through CAN tool or LCD)
Float Charge Phase
13.4 VDC
Condition (Equalization) Phase
N/A
N/A
N/A
N/A
Table 3 Battery Charger Recipes with BTS
12LPC15 Manual
Gel
SEE SPEC
13.7 VDC
14.6 VDC
5mv/cell/°C
24.5 VDC @
15.0 VDC
-6°C
@ 10°C
13.4 VDC
13.2 VDC
5mv/cell/°C
4 hours
N/A
15.5 VDC
30.24 mV/
N/A
N/A
4 hours
N/A
Control
Wet
LFP
14.4 VDC
N/A
0.5 hours
13.6 VDC
N/A
N/A
N/A
N/A
cell/°C
N/A
Manual
N/A