AC Input/Output Connections

WARNING: Damage to the power inverter will occur if an external AC power source is applied to the inverter's
AC hardwire output.
WARNING: Do not directly connect another source of AC power to the AC output of the inverter. This will
result in damage not covered under warranty.
GFCI
A 20 A GFCI is installed into the side of the inverter, except for hardwire-only versions ("H" suffix) where the
GFCI is omitted. The rated output of the inverter is 12.5 A. The 12LPC15 allows for 20 A of bypass current. If
20 A of load is connected to the inverter or inverter/charger while in inverter mode, the inverter will shut down in
overload.
Hardwire Interface
1. Remove the cover for hardwire AC wiring.
2. Insert the AC input and output wiring through the AC output cable clamps to protect the wires from the metal
edge of the hole.
3. Connect the AC wiring with the provided wire nuts.
4. Check that the AC input wiring is connected correctly. Red is AC hot and gray is AC neutral.
5. Check that the AC output wiring is connected correctly. Black is AC hot, white is AC neutral, and green is
ground. Use minimum 12 AWG when connecting to the inverter/charger input and output.
Figure 5 Hardwire Access
Figure 6 AC Inverter Output Connections