Default Configurations - Sensata Dimensions 12LPC15 Owner's Manual

Dc to ac power inverter/charger pure sine wave output
Hide thumbs Also See for Dimensions 12LPC15:
Table of Contents

Advertisement

Configurations
Low Batt
BCR
AC Line Qualify
CAN Instance
Baud Rate
Settings
Battery Profile
Default CV
Min CV
Max CV
Default CV Timer
Min CV Timer
Max CV Timer
Default Float V
Min Float V
Max Float V
Battery Type
LFP
LFP
LFP
LFP
*The NVM Setup Utility can be used to adjust the temperature only in Celsius.
0.1C charging is the feature in which the charger will reduce the charge current to ten percent of the amp hour
rating. See the specification table for the default amp hour setting. The amp hour setting may be adjusted with CAN
or the NVM Setup Utility.
Page 26
Options
10.0 V
to
5 A
to
5 secs
to
1
to
250k
or
Table 6 Setting Options
Wet
1
14.6 VDC
14.5 VDC
12.0 VDC
12.0 VDC
15.4 VDC
15.3 VDC
6.0 hrs
0.5 hrs
25.0 hrs
13.4 VDC
13.5 VDC
12.0 VDC
12.0 VDC
14.2 VDC
14.3 VDC
Table 7 Battery Charger Customization Options
High Temp
Profile
Shutdown*
1
45°C/113°F
2
45°C/113°F
3
60°C/140°F
4
60°C/140°F
Table 8 LFP Setting Options
12LPC15 Manual
Increment
13.0 V
.1 V
20 A
5 A
30 secs
5 secs
13
1
500k
N/A
Battery Type
AGM
1
14.1 VDC
12.0 VDC
14.9 VDC
6.0 hrs
6.0 hrs
0.5 hrs
0.5 hrs
25.0 hrs
25.0 hrs
13.6 VDC
12.0 VDC
14.4 VDC
Cold Temp
Shutdown*
0°C/32°F
None
0°C/32°F
None
Default
10.5 V (11.5 V for LFP)
15 A
30 secs
1
250k
Gel
LFP
1
See Table 10
14.4 VDC
13.9 VDC
14.8 VDC
0.5 hrs
0.5 hrs
25.0 hrs
13.6 VDC
13.3 VDC
13.8 VDC
Cold Reduced
Charge*
5°C/41°F
5°C/41°F
5°C/41°F
5°C/41°F

Advertisement