Specifications - Sensata Dimensions 12LP15 Owner's Manual

Dc to ac power inverter/charger pure sine wave output
Hide thumbs Also See for Dimensions 12LP15:
Table of Contents

Advertisement

Specifications

All ratings above assume 12.6 VDC nominal voltage, 25°C ambient temperature, and the inverter is mounted in free
air. 12.6 VDC is to be measured at the inverter input terminals.
For use at ambient temperatures less than -20°C, use the hardwire connections. The GFCI may not properly operate
at temps below -20°C.
At temperatures greater than 25°C, the inverter output is de-rated. See graph in "Operation" section of the manual.
LP units operate in inverter mode only. LPC units are able to operate in inverter mode and charge mode with
bypass.
Input Voltage (VDC)
DC Surge Voltage (VDC)
Output Voltage (VAC)
Output Frequency (Hz)
Output Waveform
Output Power (Watts Cont.)
Output Current (AAC Cont.)
Input Current (ADC Cont.)
Input Current (ADC Cont.)
Peak Power (Watts)
Peak Output (AAC)
Motor Starting Rating (h.p.)
Inverter Efficiency
Charger Input Voltage (Vrms)
Max Charger Output Current (ADC)
Input Current Bypass (Arms)
Weight (lbs.)
Dimensions in. (L x W x H)
Operating Temperature
Agency Listings
* Length includes DC terminals and handle.
** At ambient temperatures above 50°C, the inverter/charger may fail to restart in the event it shuts down in an
over temperature condition.
THD
Table 1 Specifications
< 5% at 12.6 VDC and 1500W
Pure Sine < 5% THD
Up to 167 at 12.6 VDC
Up to 190 at 10.5 VDC
65 at 12.6 VDC (LPC Only)
19.0" x 9.75" x 4.8" *
-40°C to 50°C (-40°F to 122°F) **
12LPC Manual
10.5 – 15.0
Up to 24 VDC
120 +/- 5%
60 +/- .05%
1500
12.5
3000
25.0
1/2
Up to 80%
85 – 135 (LPC only)
20 (LPC Only)
30
UL458, E100666
Page 7