Vibration Safety; Connection To The Power Supply - F.F. Group RH 2-26 PLUS Original Instructions Manual

Hide thumbs Also See for RH 2-26 PLUS:
Table of Contents

Advertisement

Available languages
  • EN

Available languages

  • ENGLISH, page 6
RH 2-26 PLUS | RH 2-26 FC PLUS
tool. Loss of control can cause personal injury.
Hold the tool by the insulated gripping sur-
f
faces when performing operations where the
application tool or the screw could contact hid-
den wiring or its own power cord. Contact with
a "live" wire will also make exposed metal parts of
the power tool "live" and shock the operator.
Connect the mains plug only when the tool is
f
switched off. After using, pull the mains plug.
Always direct the cable to the rear away from the
f
machine.
Do not carry the machine by the cable.
f
When working with the machine, always hold it
f
firmly with both hands and provide for a secure
stance.
During pauses in the work, when not in use or
f
during work on the machine itself (e.g., changing of
the working tools, repairs, cleaning, adjustment),
pull the mains plug.
Persons under 16 year of age are not permitted to
f
operate this machine.
Keep the tool accessories out of the reach of chil-
f
dren.
Only use original accessories
f
ADDITIONAL SAFETY AND WORKING IN-
STRUCTIONS
Observe correct mains voltage! The voltage of
f
the power source must agree with the voltage
specified on the nameplate of the machine.
Power tools marked with 230 V can also be op-
erated with 220 V.
Use appropriate detectors to determine if
f
utility lines are hidden in the work area or call
the local utility company for assistance. Con-
tact with electric lines can lead to fire and electric
shock. Damaging a gas line can lead to explosion.
Penetrating a water line causes property damage.
Firmly tighten the auxiliary handle, hold the
f
machine firmly with both hands while work-
ing and keep proper footing and balance at all
times. The machine is securely guided with both
hands.
Secure the workpiece. A workpiece clamped with
f
clamping devices or in a vice is held more secure
than by hand.
For drilling without impact in wood, metal, ceramic
f
and plastic as well as for screwdriving, tools with-
out SDS-plus are used (e.g., drill bits with cylindrical
shank). For these tools, a keyless chuck or a key type
drill chuck are required.
The quick change chuck is automatically locked.
f
Check the locking effect by pulling the quick
change chuck.
Inserting SDS-plus Drilling Tools: Check the
f
latching by pulling the tool.
Replace a damaged dust protection cap imme-
f
diately. The dust protection cap largely prevents
the penetration of drilling dust into the tool hold-
er during operation. When inserting the tool, pay
attention that the dust protection cap is not dam-
aged.
Dust from materials such as lead-containing
f
coatings, some wood types, minerals and met-
al can be harmful to one's health and cause al-
lergic reactions, lead to respiratory infections
and/or cancer. Materials containing asbestos may
only be worked by specialists.
As far as possible, use a dust extraction system
ƒ
suitable for the material.
Provide for good ventilation of the working place.
ƒ
It is recommended to wear a P2 filter-class respi-
ƒ
rator.
Observe the relevant regulations in your country
for the materials to be worked.
Prevent dust accumulation at the workplace.
f
Dust can easily ignite.
Apply the power tool to the screw only when it
f
is switched off. Rotating tool inserts can slip off.
If the application tool should become blocked,
f
switch the machine off. Loosen the application
tool.
Before switching on the power tool, make sure
f
that the application tool moves freely. When
switching on with a blocked drilling tool, high
torque reaction can occur.
To save energy, only switch the power tool on when
f
using it.
Always wait until the machine has come to a
f
complete stop before placing it down. The tool
insert can jam and lead to loss of control over the
power tool.

VIBRATION SAFETY

This tool vibrates during use. Repeated or
longterm exposure to vibration may cause tem-
porary or permanent physical injury, particularly
to the hands, arms and shoulders.
TO REDUCE THE RISK OF ANY VIBRATION-RE-
LATED INJURY:
First be examined by a doctor and then have regu-
ƒ
lar medical check-ups to ensure medical problems
are not being caused or worsened from use. Preg-
nant women or people who have impaired blood
circulation to the hand, past hand injuries, nervous
system disorders, diabetes, or Raynaud's Disease
should not use this tool. If you feel any symptoms
related to vibration (such as tingling, numbness,
and white or blue fingers), seek medical advice as
soon as possible.
Use tools with the lowest vibration when there is
ƒ
a choice.
Take vibration-free breaks during each day of work.
ƒ
Grip tool as lightly as possible (while still keeping
ƒ
safe control of it). Let the tool do the work.

CONNECTION TO THE POWER SUPPLY

Make sure the power supply information on the
machine's rating plate are compatible with the
power supply you intend to connect it to.
This appliance is Class II* and is designed for con-
nection to a power supply matching that detailed
on the rating label and compatible with the plug
fitted. If an extension lead is required, use an ap-
proved and compatible lead rated for this appli-
ance. Follow all the instruction supplied with the
extension lead.
*Double insulated: This product requires no
earth connection as supplementary insu-
lation is applied to the basic insulation to
English |