Nick Maciariello
January 31, 2025
Where on the back of the ready rack extractor dose the dosing hose attach. There are 4 connections, which one does the detergent hook to. We have a OPL basic pump
1 comments:
Mr. Anderson
May 14, 2025
The dosing hose on the back of the Seko OPL BASIC ready rack extractor attaches as follows:
For liquid products: - The 8x12 mm dosing hose connects to the right side (output side) of the pump and runs to the injection point on the washing machine. - Another 8x12 mm hose connects from the left side (suction side) of the pump to the chemical product source.
For solid or powder detergents: - A 4x6 mm copper tube (not supplied) is used to connect: - From the hydraulic water supply to the inlet of the water solenoid valve. - From the outlet of the solenoid valve to the solid detergent feeder. - Then, another hose from the feeder’s outlet goes to the elbow connector on the OPL BASIC system.
It’s important to: - Use a foot filter on the suction line and ensure it reaches the bottom of the chemical container. - Tighten all compression nuts carefully to avoid leaks (but avoid overtightening).
Would you like a diagram to better visualize the connections?
Need help?
Do you have a question about the OPL BASIC and is the answer not in the manual?
Questions and answers
Where on the back of the ready rack extractor dose the dosing hose attach. There are 4 connections, which one does the detergent hook to. We have a OPL basic pump
The dosing hose on the back of the Seko OPL BASIC ready rack extractor attaches as follows:
For liquid products:
- The 8x12 mm dosing hose connects to the right side (output side) of the pump and runs to the injection point on the washing machine.
- Another 8x12 mm hose connects from the left side (suction side) of the pump to the chemical product source.
For solid or powder detergents:
- A 4x6 mm copper tube (not supplied) is used to connect:
- From the hydraulic water supply to the inlet of the water solenoid valve.
- From the outlet of the solenoid valve to the solid detergent feeder.
- Then, another hose from the feeder’s outlet goes to the elbow connector on the OPL BASIC system.
It’s important to:
- Use a foot filter on the suction line and ensure it reaches the bottom of the chemical container.
- Tighten all compression nuts carefully to avoid leaks (but avoid overtightening).
Would you like a diagram to better visualize the connections?