Nortel Meridian 1 Manual page 44

Telephone and attendant console installation
Table of Contents

Advertisement

Page 32 of 224
Attendant consoles
Table 4
QCW and M1250 attendant console cross-connections (Part 2 of 2)
Mounting cord
Lead
designation
Emergency
transfer
Spare
Spare
Spare
Spare
Major
Alarm
GND
GND
spare
Note 1: The 15-V and 25-V supplies can be obtained at the cross-connect terminal when a QUT1 power
supply is provided.
Note 2: The 25-V supply can also be obtained from two additional units on a line circuit card.
Note 3: Connect to Pin 3 or 28 of the appropriate PFJ5 terminal block.
Note 4: Connect TC to Pin 29 or 5 and ALM to Pin 4 or 31 of the appropriate PFJ5 terminal block.
Note 5: This applies to QPC297 and QPC61 circuit cards.
553-3001-215 Standard 10.00 June 1999
Pin
Pin
number
number
36
36
11
11
37
37
12
12
38
38
13
13
39
39
14
14
40
40
15
15
41
42–45
16
16–2
16/25-pair Connector Cable
Pair
Color
number
11T
BK-BL
R
BL-BK
12T
BK-O
R
O-BK
13T
BK-G
R
G-BK
14T
BK-BR
R
BR-BK
15T
BK-S
GND
R
S-BK
16T
Y-BL
R
BL-Y
Connected to
GND (Note 3)
TC (Note 4)
GND (Note 3)
ALM (Note 4)
See static discharge
Installation procedure

Advertisement

Table of Contents
loading

This manual is also suitable for:

M2317M3000M2616ct