2x7 pin connector
Power board
11
12
13
Inside Phone Base
Display board
If the phone is equipped with the External Alerter Option, you must
remove it before installing the ATA. The External Alerter Option board
is located at the right center of the telephone:
• Remove the screws from the External Alerter Option board.
• Grasp the board firmly on each end and pull upward to remove
from the 2X3 pin connector
Install the Jumper board on the 2X7 pin connector inside the phone set
base.
• There are 2 Jumper boards provided. Use the brown Jumper
board for the NTZKxxxx phone set and the black Jumper board
for the NT2Kxxxx phone set with a date code prior to January
1998.
• If a Power Option board was not installed on the NT2Kxxxx and
the NTZKxxxx there will be 2 Jumper plugs on the 2X7 pin
connector that must be removed before installing the Jumper
board.
Remove the knockout located on the back panel of the footstand in
order to install the ATA. It is the smaller knockout, located inside the
large knockout. The small ATA knockout can be remove by pressing it
in with thumb presser.