4.15.4 Audible Driver Module - Dual Output type

In order to drive audible indicators, an Audible Driver Module Kit of Parts (KOP) is
required – Siemens part number 667/1/32955/000. The module is powered from
the phase Green of the relevant pedestrian phase output of the LSLS card and
provides a regulated 12V DC to the audible indicators.
The module can be connected to an I/O card to allow operation to be inhibited (for
example at night), and to allow switching from Loud to Quiet audible indicators.
The Audible Driver Module will operate at both dim and bright lamp voltages.
The updated Audible Driver Module provides 4 outputs for Loud indicators and 4
outputs for Quiet indicators. A link position is normally fitted to connect these
outputs together, giving 8 audible indicator outputs which are energised whether
Loud or Quiet is selected (this gives full compatibility to the previous version of the
Module). Cutting the output link allows separate control of Loud and Quiet outputs.
Security classification
Version
Last Editor
Document Name
Copyright © Siemens plc 2020. All Rights Reserved.
CAUTION
Do not touch components on the Module: voltages of up to 81V peak
could be present, and components could be hot
Quiet Audible +ve
Audible -ve
Figure 31 – Audible Driver Module
Unrestricted
7
manpreet.jeerh
ST950 ICM Handbook
Mobility, Intelligent Traffic Systems
Sopers Lane, Poole, Dorset, BH17 7ER
Quiet PP LED
Loud Audible +ve
Page
Status
Date
Document No.
Mobility is a division of Siemens Plc
Loud PP LED
Output link
67 of 154
Issued
January 2020
667/HE/45950/000