Monitored Audibles - Single Output Type - Siemens ST950 Handbook

Hide thumbs Also See for ST950:
Table of Contents

Advertisement

Audible 1
Audible 8
* Only on /002 variant of Module
Figure 29 – Audible Driver Module Connections – Single Output type
4.15.2 Monitored Audibles – Single Output type
The /002 variant of the Audible Driver Module has an opto-isolated Monitor Output
that is open-circuit when the audible is voltage is less than 5V and short-circuit
when the audible output has a voltage present of more than 5V. This allows
independent monitoring of the voltage on the audible output. The Monitor Output
can be wired directly to an input of the I/O card.
Security classification
Version
Last Editor
Document Name
Copyright © Siemens plc 2020. All Rights Reserved.
Audible
Driver
Module(s)
(4 max)
+
Audible +
-
Audible -
+
Audible +
-
Audible -
Mon Ret *
Unrestricted
7
manpreet.jeerh
ST950 ICM Handbook
Mobility, Intelligent Traffic Systems
Sopers Lane, Poole, Dorset, BH17 7ER
LSLS O/P
LSLS Return
INH -
INH +
Mon O/P *
Page
Status
Date
Document No.
Mobility is a division of Siemens Plc
LSLS
Numbered
signal output
Return
I/O Card
Common
Output
Normally Open
Input
Input
Common
65 of 154
Issued
January 2020
667/HE/45950/000

Advertisement

Table of Contents
loading

Table of Contents