10260A Series Actuators Installation, Operations, and Maintenance Manual
Physical
Output Torque/Full Travel
Stroking Time
Electrical
Power Input
Motor
Motor Current
Loss of Power
Local Auto/Manual Switch
Limit Switches
Auxiliary Switches
Certifications
CE Compliance
NEMA 4
Torque Settings of Crank Arm Bolts
Clamp Bolt
Rod End Bolt
8
10260A Series Actuators – Installation, Operations, and Maintenance
Model #
10261A
10262A
10264A
10266A
10267A
10268A
10269A
10263A
10265A
120 Vac single phase, 50 or 60 Hz
240 Vac single phase, 50 or 60 Hz
Instant start/stop, non-coasting, non-burnout, continuous duty permanent magnet
synchronous induction motor. Can be stalled up to 100 hours without damage.
= No load = full load = locked rotor
Model No.
10261A, 62A, 64A, 66A
10263A, 10265A
10267A, 68A, 69A
Stays in Place
Optional - allows local and automatic operation of the actuator.
Standard - Two SPDT end of travel limits rated (10 A at 125 Vac, 5 A at 250 Vac).
Optional - Up to 4 additional SPDT switches rated (10 A at 125 Vac, 5 A at 250 Vac)
89/336/EEC EMC Directive, 73/23/EEC Low Voltage Directive.
Optional
Standard Arm (p/n 087449) (1-7/16–5 in. adjustment): 85 lb.-ft.
Optional Long Arm (p/n 154007) (0–12 in. adjustment): 85 lb.-ft.
Standard and long arms: 30-35 lb.-ft
Torque
Lb.-ft
N-M
10
15
20
27
40
55
60
80
40
55
80
110
150
200
200
270
300
400
120 V, 50/60 Hz
0.4 A (48 VA)
1.0 A (120 VA)
0.8 A (96 VA)
Output Shaft Speed sec/90°
@ 60Hz
@ 50Hz
10
12
20
24
40
48
60
72
20
24
40
48
60
72
40
48
60
72
240 V, 50/60 Hz
0.3 A (24 VA)
1.0 A (60 VA)
0.3 A (36 VA)
2/03