PV-IB_IT_英表示-3.3 08.3.6 10:14 ページ94
5.3.7 Setting Address Number - RS485 interface with external device
D I SPL AY MODE
1
DEV I CE ADDRESS
2
DEV I CE ADDRESS
DEV I CE ADDRESS
3
Display panel
[ Wh ] /
[ kW ]
*
k
( 0 1 )
lashing
( 0 1 )
lashing
( 0 1 )
lashing
Procedure
Press the POWER and ENTER switch
for 2 seconds or longer.
Then"DISPLAY MODE"is displayed
on the LCD.
Press the ENTER switch 2 times.
Then"DEVICE ADDRESS" is dis-
played on the LCD.
1. Each push of the SELECT switch
changes the flashing number:
→ 1 → 2 → ...9 → 0
2. Pressing the MODE switch causes
another digit to start flashing.
Repeat the procedure to bring up the
desired number, some one between 1
and 30.
RS485 switch in the rearmost PV
Inverter is ON and other PV Inverters
are OFF.
odular jack for RS485
interface
RS485 switch
94
DC - terminal
RS485
ON
OFF