Installation checklist
Contents of this chapter
This chapter contains a checklist of the mechanical and electrical installation of the drive.
Checklist
Examine the mechanical and electrical installation of the drive before start-up. Go through
the checklist together with another person.
WARNING!
Obey the safety instructions of the drive. If you ignore them, injury or death,
or damage to the equipment can occur. If you are not a qualified electrical
professional, do not do installation or maintenance work.
WARNING!
Stop the drive and do the steps in section
before you start the work.
Make sure that ...
The ambient operating conditions meet the drive ambient conditions specification, and enclosure rating
(IP code or UL enclosure type).
The supply voltage matches the nominal input voltage of the drive. See the type designation label.
The insulation resistance of the input power cable, motor cable and motor is measured according to
local regulations and the manuals of the drive.
The drive cabinet is attached to the floor, and if necessary due to vibration etc, also by its top to the
wall or roof.
If the drive is connected to a network other than a symmetrically grounded TN-S system: You have
done all the required modifications (for example, you may need to disconnect the EMC filter or ground-
to-phase varistor). See the electrical installation instructions in the supply unit manual.
Installation checklist 49