Programming
5� Highlight OUTPUT SOUOCE and press ENTEO� One or more options are
available, depending on the flow computer model�
6� Highlight an output source and press ENTEO�
7� Press BACKSPACE to return to the CH1 Output Parameter menu�
8� To edit the remaining parameters:
a� Highlight the parameter (Pulse Full Scale, Pulse Low Scale or Pulse Max
Frequency,) and press ENTEO�
b� Use the soft keys and numeric keypad to enter a value and press ENTEO to
save the value�
9� On the confirmation screen, press ENTEO to confirm the change�
Oelay Output Configuration
The relay output can be configured:
• To control On/Off functions of devices such as lights, buzzers, pumps and fans�
• As a totalizing point�
• As a manual control for remote switches and buttons�
To set up the relay output, first select a relay mode, then edit the parameters
available for that relay mode�
1� Navigate to SYSTEM SETUP > ADVANCED SETUP > RELAY OUTPUT >
CH1 RELAY MODE�
The relay mode options are:
Option
Disable Relay
Totalizer
High Alarm
Low Alarm
High/Low Alarm
Manual
2� Highlight a relay mode and press ENTEO�
3� Press BACKSPACE to return to the Relay Output menu�
Page 32
Description
No output
Totalizer output
On/Off function tripped at high point
On/Off function tripped at low point
On/Off function tripped beyond a range limit
On/Off function of manual operation