Badger Meter Orion 64989-002 Installation & Operation Manual
Badger Meter Orion 64989-002 Installation & Operation Manual

Badger Meter Orion 64989-002 Installation & Operation Manual

Automated meter reading system, transmitter for american commercial meters

Advertisement

Quick Links

®
Badger
ORION
Automated Meter
Reading System
Before Installation
with Wire Seal Security Screw
Before Installation
with Red Security Seals
IMPORTANT: This manual contains important warnings and information.
BadgerMeter,Inc.
®
®
ORION Transmitter for
Commercial Meters
READ AND KEEP FOR REFERENCE.
American
Installation &
Operation Manual
After Installation of
ORION Transmitter
After Installation of
ORION Transmitter
ORI-IOM-47
P/N 62014 Rev. 1
6-07

Advertisement

Table of Contents
loading

Summary of Contents for Badger Meter Orion 64989-002

  • Page 1 ® ® Badger ORION Installation & ORION Transmitter for Automated Meter American Operation Manual Commercial Meters Reading System Before Installation with Wire Seal Security Screw After Installation of ORION Transmitter Before Installation with Red Security Seals After Installation of ORION Transmitter IMPORTANT: This manual contains important warnings and information.
  • Page 2: Disclaimer

    P.O. Box 245036 Milwaukee, WI 53224-9536 Telephone: (414) 355-0400, (800) 876-3837 Fax: (888) 371-5982 On the Web: www.badgermeter.com or call your local Badger Meter representative. Product Identification Information Record the product identification numbers from the nameplate. Transmitter Model Number _ ______...
  • Page 3: Table Of Contents

    Table of Contents Disclaimer ..........................2 Questions or Service Assistance ....................2 Product Identification Information ....................2 Note Explanations ........................5 Scope of Manual ........................5 Product Unpacking and Inspection..................... 5 License Requirements ....................... 5 ® Badger ORION Integral Transmitter/Hardcase Gas Meter Identification ........6 ®...
  • Page 4 (This page intentionally left blank)
  • Page 5: Note Explanations

    Proper performance and reliability of the Any changes made, but not approved by Badger ORION system depends upon Badger Meter, can void the user’s authority to installation in accordance with these operate the equipment. instructions. Product Unpacking and Inspection...
  • Page 6: Badger ® Orion Integral Transmitter/Hardcase Gas Meter Identification

    ® ® Badger ORION Integral Transmitter/Hardcase Gas Meter Identification Badger ORION integral transmitters for gas meters are designed for use with only two major brands of hardcase gas meters. Please refer to and use the following identification table. Identification Table American Badger ORION Gas Meter Manufacturer...
  • Page 7: American

    AMERICAN Commercial Diaphragm and Turbine Meters ® with Wire Seal Security Screw Index and Index Cover Plate Removal from American Meter with Seal Security Screw Step 1: Remove the wire security seal from the index cover mounting screw. American Commercial Diaphragm and Turbine Meter with Wire Seal Security Screw Step 2: Use a large screwdriver to remove the four (4) 18-8 index cover mounting plate...
  • Page 8: Badger Orion Transmitter Label

    ® ® Badger ORION Transmitter Label Install the Badger ORION Transmitter and American Cover Plate If the utility chooses to add an additional Use care when handling the Badger ORION label, follow steps A, B, and C below. If not, transmitter to insure the drive pawl is not go to Install in the next column.
  • Page 9: Program The Badger Orion Transmitter

    Step 3: Be sure the gas INLET markings are Step 6: Index and cover has two platic seal on the same side of the meter and the lens caps that are difficult to maneuver around with faces forward. the long bolts. Place two of the screws, without washers, through the white seal caps.
  • Page 10: Complete The Installation

    Complete the Installation After programming, add seal caps to the front and rear screws of the index cover plate. Only the front screw is shown below. If the index mounting seal caps were removed, replace them with the extra caps provided in the installation kit.
  • Page 11: American

    ® AMERICAN Commercial Diaphragm and Turbine Meters with Red Security Seals Index and Index Cover Plate Removal from American Meter with Red Security Seals Step 1: Use a large screwdriver to remove the four (4) 18-8 index cover mounting plate screws and American Index.
  • Page 12: Badger Orion Transmitter Label

    Badger ® ORION ® Transmitter Label Install the Badger ORION Transmitter and If the utility chooses to add an additional American Cover Plate label, follow steps A, B, and C below. If Use care when handling the Badger ORION not, go to Install in the next column. transmitter to insure the drive pawl is not subjected to any physical abuse.
  • Page 13: Program The Badger Orion Transmitter

    Step 6: Tighten all screws evenly with a large Step 3: Be sure the gas INLET markings are screwdriver to approximately 70 inch-lbs. on the same side of the meter and the lens faces forward. Gas INLET markings Lens facing forward Step 4: Place the American ®...
  • Page 14: Complete The Installation

    Complete the Installation After programming, add seal caps to the front and rear index cover screws . Only the front screws are shown below. If the index mounting screw seal caps were removed, replace them with the extra caps provided in the installation kit. This completes the installation of a Badger ®...
  • Page 15 (This page is intentionally left blank)
  • Page 16 Badger Meter, Inc. Due to continuous research, product improvements and enhancements, Badger Meter reserves the right to change product or system specifications without notice, except to the extent an outstanding contractual obligation exists. Please see our website at www.badgermeter.com...

Table of Contents