Fault Table - Bosch SYEPS 1X Series Operating Instructions Manual

Highly dynamic electrohydraulic punching system for nc punching machines
Table of Contents

Advertisement

Fault
High temperatures
Temperature shutdown in normal
operation while the power is
reduced and generation of noise
increased
Blocking and non-linear
characteristics of the high-
response valve
Vibration on the main stage of the
high-response valve
Malfunction or destruction of
electronic components
Punching axis does not move or
moves in an uncontrolled manner
or vibrates

14.3 Fault table

Possible cause
Reduced cooling capacity due to insufficient
air circulation at the power unit
Continuous operation with idle strokes or
inappropriate stroke lengths
Great leakage in the system.
Defective components
Contamination in the hydraulic system
High-response valve damaged/defective
High-response valve damaged/defective
Excessive vibration stress on the machine
Incorrect wiring
Incorrect installation of electronics and wiring Check for correct installation and wiring and, if
Electrical signals are not received
Loose connection at valve plug-in connector
HNC100 not ready for operation
Incorrect gas pressure in the hydraulic
accumulator
Improper operation of the high-response valve Test function of the high-response valve in open-
Accumulator discharge valves not closed
Accumulator charging valve is not actuated
properly
Troubleshooting 123/132
Remedy
Ensure sufficient ventilation for the power unit at
the place of installation
Minimize operation with idle strokes, select
suitable stroke lengths
Locate and eliminate leakage
Replace defective components
Examine oil cleanliness
Test function by open-loop-controlled operation as
described in Chapter 8 "Commissioning"
In open-loop controlled operation, the actual valve
value provides information whether the valve is
damaged so heavily that it vibrates. If defective,
the valve must be replaced.
Do not exceed the permissible vibration stress
(during initial commissioning of a new machine
series, the permissible vibration should be
checked in cooperation with Bosch Rexroth).
Inspect wiring and check electrical signals with the
help of measuring equipment and the diagnosis
function of WIN-PED®. If required, replace
electronic components and correct wiring.
required, correct.
Check electronics installation and wiring and, if
required, correct.
Check mounting of plug-in connector and, if
required, re-tighten.
Inspect plug-in connector for cold solder points
and cable break. If required, install tested cables.
Check that the HNC100 is properly connected and
switched on.
Check gas pressure (see page 123)
loop-controlled operation with the HNC100 or
VT-VET-1.
If the high-response valve properly follows the
valve command value with both, a small valve
aperture (slow traversing) and large aperture (fast
traversing), the valve is ok.
Check and, if required, correct, connection cables.
Check accumulator discharge valves and close
them, if open.
Check function and actuation of the accumulator
charging valve.
RE 30201-B/07.2014, SYEPS series 1X, Bosch Rexroth AG