C24EA SERIES ELECTRIC COUNTER CONVECTION STEAMERS
INSTALLATION CODES
AND STANDARDS
In the United States, the Vulcan steamer must
be installed in accordance with:
1. State and local codes.
2. National Electrical Code (ANSI/NFPA No.70,
latest edition) available from the National
Fire Protection Association, Batterymarch
Park, Quincy, MA 02269.
3. Vapor Removal from Cooking Equipment,
(NFPA-96, latest edition) available from
NFPA.
In Canada, the Vulcan steamer must be installed
in accordance with:
1. Local codes.
2. Canadian Electrical Code (CSA C22.2 No.3,
latest edition) available from the Canadian
Standards Association, 5060 Spectrum Way,
Mississauga, Ontario, Canada L4W 5N6.

LOCATION

Allow space for plumbing and electrical
connections. Minimum clearance is 6" (15.2
cm) on the back for proper air circulation. Allow
adequate access for operating and servicing the
steamer (36" at the front of the steamer, 15" (38
cm) above the steamer and 18" (45.7 cm) on
right side of steamer).

LEVELING FEET

This steamer is shipped with four 2" leveling
feet. Optional 4" leveling feet are available.
The 2" feet can be removed and the optional 4"
feet can be threaded into holes on the bottom
of the unit.

LEVELING

Using a spirit level or pan of water in the bottom
of the steamer, adjust the leveling feet or the
feet on the adjustable legs to level the steamer
side to side with a slight tilt front to back to
allow for proper cavity draining. After the drain
is connected, check for level by pouring water
onto the fl oor of the compartment. All water
should drain through the opening at the back
of the compartment cavity.
Steamer must be installed level
side to side with a slight tilt front to back
to allow for proper draining.

ANCHORING STEAMER

1. Place steamer in the desired location on
the countertop and mark four corners.
Remove the steamer and drill
indicated in Figure 1.
2. Apply a bead of RTV or other NSF approved
sealant around the bottom edge of the
steamer. If anchoring the steamer, this
bottom seal is necessary to meet NSF
requirements.
3. Set steamer on countertop and bolt down
securely with

STACKING STAND

Instruction to install convection steamers on
stacking stand are included with the stacking
stand.
— 6 —
/
" holes as
1
2
/
" by 16" bolts (not supplied).
3
8
Figure 1