Electrical Connection - Vulcan-Hart C24EA Series Installation & Operation Manual

Electric counter convection steamers
Hide thumbs Also See for C24EA Series:
Table of Contents

Advertisement

ELECTRICAL CONNECTION

Electrical and
grounding connections must comply
with the applicable portions of the
National Electrical Code and/or other
local electrical codes.
Total
Volts
Hz
Ph
KW
8.5
208
50/60
8.5
240
50/60
8.5
208
50/60
8.5
240
50/60
8.5
480
50/60
9.25
208
50/60
9.25
240
50/60
9.25
208
50/60
9.25
240
50/60
9.25
480
50/60
15
208
50/60
15
240
50/60
15
208
50/60
15
240
50/60
15
480
50/60
15.75
208
50/60
15.75
240
50/60
15.75
208
50/60
15.75
240
50/60
15.75
480
50/60
2002 National Electric Code
*Dual Element Time-Delay Fuse or Inverse Time Circuit Breaker
Circuit Size (minimum) & Fuse/Circuit Breaker Size (maximum) compiled in accordance with the
National Electrical Code (ANSI/NFPA 70), 2002 Edition.
KW Per Phase
L1-L2
L2-L3
L3-L1
1
1
3
4.25
2.12
2.12
3
2.83
2.83
2.83
3
2.83
2.83
2.83
1
1
3
4.25
2.69
2.12
3
2.83
3.58
2.83
3
2.83
3.58
2.83
1
1
3
7.50
3.75
3.75
3
5.00
5.00
5.00
3
5.00
5.00
5.00
1
1
3
7.50
4.31
3.75
3
5.00
5.75
5.00
3
5.00
5.75
5.00
C24EA SERIES ELECTRIC COUNTER CONVECTION STEAMERS
The wiring diagram is located on the right side
panel as you face the steamer. This steamer is
hard wired.
Rated Amps
3-Phase Amps Per Line
L1
L2
L3
26.54
26.54
17.70
20.50
20.50
20.50
10.30
10.30
10.30
26.54
28.88
20.04
20.45
23.15
23.15
10.21
11.57
11.57
46.84
46.84
31.23
36.08
36.08
36.08
18.04
18.04
18.04
46.84
49.18
33.57
36.08
38.79
38.79
18.04
19.40
19.40
— 7 —
Single
Circuit
Fuse
Phase
Size
Size or
Amps
Circuit
Breaker
Size*
(Amps)
40.87
60
60
35.42
50
50
35
35
30
25
15
15
43.57
60
60
38.54
50
50
35
35
30
30
15
15
72.12
90
90
62.50
75
75
60
60
50
50
25
25
74.82
90
90
65.63
80
80
60
60
50
50
25
25
90°C
Copper
Min.
Wire
Size
8
8
10
10
16
6
8
10
10
16
4
6
6
8
14
4
4
6
8
14