5. Pour deliming solution into the steam
generator slowly to avoid spillage.
6. Remove funnel from delime port then rinse
port with clean water.
7. Lightly coat delime port threads with Petrol-
Gel then install delime port cap. Cap must
be installed and tightened securely at all
times.
8. Turn power switch ON.
9. When ready light comes on, turn cooking
timer on for 3 minutes to delime the steam
tubes and nozzles.
10. After 40 minutes, turn power switch OFF and
allow steam generator to completely drain,
15 minutes.
11. Rinse steam generator with clean water:
A. Turn power switch ON. When ready light
comes on, turn cooking timer on for 3
minutes to rinse the steam tubes and
nozzles.
B. Turn power switch OFF and allow steam
generator to completely drain.
C. Turn cooking timer to OFF.
D. Repeat steam generator rinse one time.
12. Clean exterior and interior using a mild
solution of soap and water. Rinse with clean
water then dry with a soft cloth.
13. Leave compartment door open when not in
use.
14. The steamer is ready for operation or
shutdown.
C24EA SERIES ELECTRIC COUNTER CONVECTION STEAMERS

DOOR GASKET

If the door gasket is leaking due to a nick or
cut, it must be replaced. Damage to the gasket
sealing surface will cause steam leakage.

DRAINING STEAM GENERATOR

Drain the steam generator at the end of each
day to fl ush out minerals and minimize scale
build-up. The generator drains automatically
for approximately 15 minutes after the power
switch is turned.