JLG 25RTS Service & Maintenance page 50

Hide thumbs Also See for 25RTS:
Table of Contents

Advertisement

SECTION 2 - PROCEDURES
3. Insert disconnect rod into cover cap.
4. Set cover on table, exterior side up. Place cover cap
onto cover, aligning pipe plug hole in cover cap over
pipe plug hole in cover.
5. Place two cover cap bolts into any two bolt holes
180 degrees apart on cover cap, then tighten bolts.
6. Torque both bolts to 4 - 5 Nm (36 - 49 in. lbs.).
7. With large end down, place disconnect cap onto
cover cap, aligning pipe plug hole in disconnect cap
over pipe plug hole in cover cap.
2-34
8. Place two remaining bolts into bolt holes in discon-
nect cap, and tighten bolts.
9. Torque both bolts to 4 - 5 Nm (36 - 49 in. lbs.).
10. Apply a light coat of "Never-Seize" to pipe plug and
tighten it into pipe plug hole in cover.
BEWARE OF SHARP EDGES IN COUNTER BORE WHEN INSTALL-
ING O-RING.
11. Set cover assembly on table, interior side up.
Grease o-ring and place it into counter bore around
edge of cover.
NOTE: O-ring may be stretched or pinched together to make
it fit counter bore exactly.
– JLG Sizzor –
3120826

Hide quick links: