Faults where it is not necessary to call Insinger.
You can rectify minor faults yourself following the
steps described in the table below. If you are unable
to rectify the fault, contact Insinger service
(1-800-344-4802.)
Do not open any panels or expose any parts of the
machine if tools are necessary to do so. Risk of
electric shock.
Problem
Machine continues to fill
Machine fails to fill
Wash temperature incorrect
Rinse temperature incorrect
Machine continues to wash
Machine will not drain
Machine will not start
RL-30 Undercounter December 2016
®
A
There is no soil
Connections to
blocking the
pressure switch are
pressure switch
air tight and secure
opening in tub
Water supply to unit
Solenoid valve is
is on
operating properly
Verify door is
Verify door switch is
closed
functioning properly
Verify thermostat is
Adjust thermostat
working
B1
Verify that the "de-
Verify that the rinse
lime" switch is not
temperature has
depressed
reached its set limit
Verify proper
Verify drain pump is
settings on drain
functioning properly
delay timer (KA5)
Hold start switch for
Verify S1 of cam
1 second
timer is closed
PART 5 TROUBLESHOOTING
!
Work on the electrical equipment should only be
performed by service personnel. First disconnect the
washer from the main power switch. Do not switch the
washer on again until the cause of the fault has been
identified.
WARNING:
Turn off the main switch on the dishwasher
so it is isolated from the power supply.
B
C
The pressure switch
is operating
Adjust thermostat
B2
Verify contactor is
functioning properly
Check B7 set point
Remove overflow
tube
Verify S2 of cam
timer is closed
13
www.insingermachine.com 800-344-4802
D
Verify solenoid
valve is operating
properly
Verify thermostat is
working
Verify heater is
working properly
Verify cam timer is
working properly
Verify contactor
KM3 is energized