Aumuller KS4 S12 24V DC Assembly And Commissioning Instructions

Aumuller KS4 S12 24V DC Assembly And Commissioning Instructions

Chain drive for windows
Hide thumbs Also See for KS4 S12 24V DC:

Advertisement

Quick Links

Assembly and Commissioning
Instructions
according to Machinery Directive 2006 / 42 / EC (annex VI)
KS4 S12 24V DC - C
D
hain
riVe for winDowS

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the KS4 S12 24V DC and is the answer not in the manual?

Questions and answers

Subscribe to Our Youtube Channel

Summary of Contents for Aumuller KS4 S12 24V DC

  • Page 1 Assembly and Commissioning Instructions according to Machinery Directive 2006 / 42 / EC (annex VI) KS4 S12 24V DC - C hain riVe for winDowS...
  • Page 2 Target Groups Warning and Safety Symbols Intended Use 3 - 8 Safety Instructions Data sheet KS4 S12 24V DC R Data sheet KS4 S12 24V DC L Explanations on the product label 9 - 12 Growing variants and minimum casement dimensions...
  • Page 3: Target Group

    reliminary emark bbreViationS arninG anD Safety SymbolS in theSe StruCtionS Index of abbreviations The symbols used in the instructions shall be strictly observed and have These abbreviations are used consistently throughout these assembly the following meaning: & operating instructions. Unless stated differently, all dimensions indi- cated in this document are in mm.
  • Page 4 reliminary emark ntenDeD uSe Area of application / Scope of application This drive is intended for the electromotive opening and We as manufacturers are well aware of our duties and closing of windows in facade and roof areas. responsibilities regarding the development, manufactu- The main task of this product, in combination with ring and placing of safe window drives on the market and a window and a suitable external control unit, is to...
  • Page 5 reliminary emark Hazard analysis according to DIN EN 60335-2-103 NRWG according to NRWG according to EN12101-2 with EN12101-2 without Use of the drive dual purpose for ventilation dual purpose for ventilation (1.Z.109) AUTION Natural ventilation Keep people away during closing! Installation height of drive and lower edge of casement: >...
  • Page 6: Safety Instructions

    afety nstruCtions afety inStruCtionS It is important to follow these instruc- Installation tions for the safety of persons. These These instructions address expert and safety-conscious arninG instructions shall be kept in a safe place electricians and / or qualifi ed personnel knowledgeable in for the entire service life of the products.
  • Page 7 afety nstruCtions Crush and shear points All-pole disconnecting devices shall be instal- To avoid injuries, crushing and shear points between led in the permanent electrical installation or casement and frame must be secured against entrapment external Control Unit for the drive. up to an installation height of 2,5 meters above the The mains supply lines 230 V / 400 V AC shall fl oor with appropriate measures.
  • Page 8: Ambient Conditions

    afety nstruCtions Commissioning, operation and maintenance Replacement parts, fasteners and controls After the installation and after each modifi cation in the set The drive shall only be operated with control devices from up all functions shall be checked with a trial run. It shall the same manufacturer.
  • Page 9: Data Sheet

    KS4 S12 24V DC r ata Sheet Application: natural ventilation, RWA, ferralux®-NRWG Internal intelligent cut-off switch S12 Feedback limit position „CLOSE“ (max. 24V, 500 mA) Equipment: Additional A -Click plug set for multi-drive operation umüller Options Programmable special functions Programmable feedback limit position „OPEN“...
  • Page 10: Order Data

    heet Order Data Part.-No. s [mm] L [mm] Version Finish PU / pcs. 522020 KS4 200 S12 24V R E6/C-0 KS4 300 S12 24V R E6/C-0 522030 522040 KS4 400 S12 24V R E6/C-0 KS4 500 S12 24V R E6/C-0 522050 KS4 600 S12 24V R E6/C-0...
  • Page 11 KS4 S12 24V DC l ata Sheet Application: natural ventilation, RWA, ferralux®-NRWG Internal intelligent cut-off switch S12 Feedback limit position „CLOSE“ (max. 24V, 500 mA) Equipment: Additional A -Click plug set for multi-drive operation umüller Options Programmable special functions Programmable feedback limit position „OPEN“...
  • Page 12 heet Order Data Part.-No. s [mm] L [mm] Version Finish PU / pcs. 520120 KS4 200 S12 24V L E6/C-0 KS4 300 S12 24V L E6/C-0 520130 520140 KS4 400 S12 24V L E6/C-0 KS4 500 S12 24V L E6/C-0 520150 KS4 600 S12 24V L E6/C-0...
  • Page 13 reas of PPliCation anD asement izes rowinG VariantS anD minimum CaSement DimenSionS Growing variants: Bottom-hung windows with tensile load Frame assembly Casement assembly Drive stationary Drive ride-on inward opening inward opening Frame bracket: K132 Frame bracket: Frame bracket: K134 Casement bracket: F42 Casement bracket: F42 Casement bracket: F41 swiveling...
  • Page 14: I Nstallation Step

    reParing ssembly 1: i nstallatIon step nSpeCtion before the inStallation Important instructions for a safe instal- The test procedure of drives may only be performed on a lation. Observe all instructions, wrong non-slip and secured mat or a test fi xture. During the test arninG installation may result in serious injury! run the test element must not be interfered with.
  • Page 15: Scope Of Delivery

    Torx Assembly and Commissioning Anweisung für Montage und Inbetriebnahme nach Maschinenrichtlinie 2006 / 42 / EG (Anhang VI) Instructions Tools required KS4 S12 24V DC R - K ETTENANTRIEB FÜR ENSTER • Marker, • Grains, -Click plug solution • Hammer, umüller...
  • Page 16 frame raCkets anD asement raCkets nstallatIon step imenSionS anD hole layoutS CaSement braCKetS Casement bracket F41 Casement bracket F42 Casement bracket Casement bracket    1x cylinder head 1x baseplate  screw M3x20 1x countersunk   screw M4x10 1x drilling template 1x cylinder head ...
  • Page 17 ayouts for rame raCkets anD asement raCkets K132 ole layout frame braCKetS nstallatIon step CaSement braCKet Swiveling drive mounting on the window frame - main closing edge or auxillary closing edge - inward opening windows Drillings for casement bracket and frame brackets Side view F 42 K 132...
  • Page 18 frame raCkets anD asement raCkets K134 ole layout frame braCKetS nstallatIon step anD CaSement braCKet Rigid drive mounting on the casement - main closing edge or auxillary closing edge - inward opening windows Drillings for casement bracket and frame brackets Side view K 134 F 41...
  • Page 19 inDoWs 5: a DDitional orDer for DriVe Chain nstallatIon step „ “ with Chain StretCheD on one SiDe on SiDe hunG winDowS Additional order Side-hung window with chain stretched on one side Right: Version 2 Left: Version 1 for windows DIN left for windows DIN right Part.
  • Page 20 frame raCkets anD asement raCkets ole layout CaSement braCKet nstallatIon step riVe at SiDe anDem Rigid drive mounting directly on the window frame - auxillary closing edge - inward opening windows Tandem application / Combination right / left 24 V DC view: see below FAB = max.
  • Page 21 ayouts for rame raCkets anD asement raCkets K134 + ole layout frame braCKetS nstallatIon step CaSement braCKet riVe at SiDe anDem Swiveling drive mounting on the window frame - auxillary closing edge - inward opening windows Tandem application / Combination right / left FAB = max.
  • Page 22 ounting 7: D nstallatIon step rill holeS aCCorDinG to mountinG VariantS „ Determine fastenings. Alternative: Drilling template „ Produce drill holes with appropriate cross-section. Boreholes can be made using a drilling template. The bore- For the mounting dimensions please refer to the hole intervals are shown and dimensioned on the template.
  • Page 23 ounting    „ Attach drive to the frame brackets K132 „ Slide casement bracket F42 on the baseplate   „ Secure the drive with screws and secure with screw Drive should freely swivel - between frame brackets K132 ...
  • Page 24 ounting iGiD DriVe mountinG DireCtly on the winDow frame nstallatIon step - main closing edge or auxillary closing edge - inward opening windows   „ Screw the drive onto window frame (M4). „ Slide casement bracket F42 on the baseplate ...
  • Page 25 ounting iGiD DriVe mountinG on the CaSement nstallatIon step - main closing edge or auxillary closing edge - inward opening windows  „ Fit casement bracket F41 with screws (M5). If required, use washers corresponding to the used screws. Make sure it is parallel to casement edge. „Casement bracket“...
  • Page 26 ounting iGiD DriVe mountinG on the winDow frame nstallatIon step - main closing edge - outward opening windows  „ Fit casement bracket F41 with screws (M5). If required, use washers corresponding to the used screws. Make sure it is parallel to casement edge. „Casement bracket“...
  • Page 27 able routing nstallatIon step able routinG on the CaSement or frame Cable routing on or in the casement Cable routing on the frame „ Route cable on the frame or mullion/transom. Cable on casement Cable in glazing bead Cable must be protected against damage (shearing-off, kinking, splitting).
  • Page 28: Direction Of Travel

    leCtriC ConneCtion 10: e nstallatIon step leCtriC ConnetCtion Make sure when establishing the connection that there is no voltage at the terminals! Direction of travel Polarity reversal Unused wires must be safely insulated! OPEN The running direction of the drive may be changed by interchanging (polarity reversal) the wires „BN –...
  • Page 29 leCtriC ConneCtion m-Com leCtriC ConneCtion ConfiGureD with Multi-drive operation with M-COM and locking drive - series connection Individual chain drives have an integrated cable routing with umüller connection sockets on both housing ends. configuration This enables the connect multiple drives. Remove the filler plug and Aumüller Click plug set install.
  • Page 30 leCtriC ConneCtion nstallatIon step nstallatIon step upply lineS of ontrol nit to the riVeS afety CheCK anD eSt run Observe current regulations and guidelines regarding Check the mounted system for its safety; perform test run the “Fire behavior of building materials-circuit integrity and commissioning.
  • Page 31 leCtriC ConneCtion -Click plug solution - umüller Site SupplieD CuStomiSeD ConStruCtion The a -Click plug solution enabling the use of umüller site-supplied cable. It simplifies assembly and the electrical connection of the drives.   „ Loosen the screws and remove the housing cover „...
  • Page 32: Electric Connection

    leCtriC ConneCtion M-COM (Main control unit) UniPC with configuration interface Order number: 524177 Order number: 524178 Application: Configuration module for the automatic Application: Hard- and software for configuration of configuration and monitoring of max. drives supplied by a GmbH umüller 4 opening and 2 locking drives type Rated voltage: 24V DC +/-20%...
  • Page 33: Maintenance

    aintenanCe anD rePair elp in CaSe of alfunCtionS epairS anD aintenanCe anD oDifiCation aintenanCe Professional repair of a defect drive can only be performed at the To ensure continuous function and safety of the drive periodic mainte- manufacturer’s factory or manufacturer-certifi ed specialist company. nance by a specialist company is required at least once a year (as man- Unauthorized opening or manipulation of the drive terminates warranty.
  • Page 34: D Isposal / W Arranty

    isPosal arranty emountinG arranty anD uStomer erViCe The drives are demounted by reversing the steps, as for the installation. In principal apply our: The adjustments are omitted. „General Terms for the Supply of Products and Services of the 1. Completely disconnect the system from the power supply before German Electrical Industry (ZVEI)“.
  • Page 35 ertifiCate anD eClaration of onformity The proof of the application of a quality management We declare under our sole responsibility that the product system is for company: described under "Data sheet" is in conformity with the GmbH umüller umatIc following directives: according to the certifi cation basis DIN EN 9001 as well the "Declaration of Incorporation and Conformity"...
  • Page 36 9000022001_V1.4_KW41/20...

Table of Contents