Assembly and Commissioning Instructions according to Machinery Directive 2006 / 42 / EC (annex VI) FVM2 - L OCKING DRIVE MINI FOR WINDOWS...
Page 2
Target Groups Warning and Safety Symbols Intended Use 3 - 8 Safety Instructions Data sheet FVM2 Data sheet FVM2 with specifi c application Explanations on the product label 9 - 11 Determination of locking points Inspection before the installation NSTALLATION STEP...
Children should be supervised to ensure that they are not playing with this device. Cleaning and operator’s maintenance may not be per- formed by children without supervision. Assembly Instruction FVM2...
- at the installation-site of the window. Pay attention to possible hazards on tilting or rotating windows, whose secondary closing edges are located ARNING at less than 2,5 m installation height above the fl oor, under consideration of the Control Unit and usage! Assembly Instruction FVM2...
Page 5
/ sky light. • casement size (FAB x FAH), Opening direction: inward opening, outward opening. • driving force and stroke, Profi le material: aluminum, steel, plastic or wood. • mounting site at the window frame and casement frame. Assembly Instruction FVM2...
(see it opens and closes easily! technical data). Danger spots by crush and shear points Side-hung Bottom-hung Roof windows / skyskylight domes Louvre windows Danger spots: crush and shear points according to DIN EN 60335-2-103 Assembly Instruction FVM2...
Page 7
• VDE 0100 Setting up high-voltage systems up to 1000 V ensured for maintenance work. • VDE 0815 Wiring cables • Specimen Guideline on Conduits German designation (MLAR). Assembly Instruction FVM2...
During cleaning, maintenance work and while exchanging parts the drive must be comple- tely disconnected from the power supply and secured against unintentional reactivation. Do not actuate the drive or the case- ment when repair or re-setting works are ARNING performed! Assembly Instruction FVM2...
Options Special functions programmable M-COM suitable internal Control Electronics and sequence control for drives S3 /S12 Star wiring Current of the drives does not run over FVM2 Sequence control via communication wire TECHNICAL DATA Rated voltage 24V DC (19 V ... 28 V)
FVM2 ATA SHEET ORDER DATA s [mm] L [mm] Version Finish PU / pcs. Part.-No. 17 – 36 FVM2 E6/C-0 514062 OPTIONS Special model PU / pcs. Part.-No. Drive housing painted/powder coated in other RAL colours Lump sum for coating 516030 1 –...
FVM2 Part.-No. 514063 SW-V2 (software) with M-COM suitable internal load dependent cut-off switch and sequence control for drives S3 /S12 (star wiring, drive current does not run over FVM2, sequence control via communication wire) Concealed mounting inside profi les Pre-assembled T-form coupling adapter...
Page 12
This information must be adhered. The requirements for the tightness of the windows according to EN 14359-1 must be observed! Assembly Instruction FVM2...
Page 13
It is imperative that the suffi ciently mechanical stiffness of the fastener type as well as of the swivel range of the drive is observed. AUTION If this is not guaranteed another type of fastening or another type of drive must be selected. Assembly Instruction FVM2...
Accessories for locking drive • Screwdriver (cross, Torx), • Hexagonal wrench, • Torque wrench, Assembly and Commissioning • Power drill, Instructions • Threadlock adhesive, • possibly a tool for blind rivet nuts. Warning sign sticker „Risk of entrapment“ (1x) Assembly Instruction FVM2...
Page 15
PPLICATION EXAMPLES Hole layouts (Application examples) Concealed mounting inside profi les Concealed mounting inside profi les Concealed mounting inside profi les outward opening windows outward opening windows outward opening windows FVM2 FVM2 FVM2 See: I See: I See: I NSTALLATION NSTALLATION...
Page 16
OLE LAYOUTS FVM2 NSTALLATION STEP OLE LAYOUTS FOR LOCKING DRIVE Hole layout - Concealed mounting inside profi les - Mounting bottom in the frame profi le Window top-hung inward opening horizontal pivot See: versions top-hung outward opening vertical pivot NSTALLATION STEP...
Page 17
ONCEALED MOUNTING INSIDE PROFILE SWITCHES SETTING NSTALLATION STEP ILLING LAYOUT FOR CONCEALED MOUNTING INSIDE PROFILES Milling layout for locking drive FVM2 - Concealed mounting inside profi les View without FVM2 Remove ribs. Screw surface must be fl at. Milling depth is dependent on the window profi le...
Page 18
DIP switches setting: moving direction and locking stroke - stroke (s) = 17 ±1 Factory settings M-COM or LK3 Recognition undercurrent ISCONTINUED PRODUCT Opening drive locking Terminal 3 = FVM2 s = 17±1 plate connection optional DIP switch OPEN CLOSE DIP switch 1 :...
Page 19
4 N/m Assembly locking drive FVM2 DIP switches setting In a voltage-free state: Set the DIP switches correctly, when not mounted the locking drive FVM2 (see chapter: „DIP SWITCHES SETTING OVING DIRECTION AND THE FVM2 locking pin “).
Page 20
FVM2 with the traverse path of the on-site locking bar moves synchronously. - in CLOSE direction. Switch the control voltage - from the locking drive FVM2 - If necessary, correct the locking stroke and the locking position - with the DIP switches.
Page 21
Assembly locking drive FVM2 locking bar 4 N/m DIP switches setting In a voltage-free state: Set the DIP switches correctly, when not mounted the locking drive FVM2 (see chapter: „DIP SWITCHES SETTING OVING DIRECTION AND THE “). LOCKING STROKE...
Page 22
SSEMBLY OF A PREPROGRAMMED SET Switch on the control voltage at locking drive FVM2 Test run: locking drive FVM2 Close the casement manually. During the test run and at the opening drive - in CLOSE direction. First the opening drive moves in CLOSE direction, then press the casement fi xed to the frame.
Page 23
the closed state. the groove of the gear wheel (bevel pinion). For concealed mounting of the locking drive FVM2 FVM2 inside profi les, drill a hole in the window frame, to access the unlocking mechanism. Drill hole in the window frame min.
(polarity reversal) the wires „BN – (brown)“ violet - „BU – (blue)“. grey Connection assignment from the opening drive Connection assignment from the locking drive FVM2 Opening drive WH is used for communication in systems with synchronized WH is used for communication multi-drive operation.
Page 25
- 5 piece • Flexible cable length • Connect multiple drives • Torsion-plug • Locking hooks prevent withdrawal of the plug under tensile load • Strain relief by screwing Ø5 the housing halves ac- cording DIN EN 60335-1 Assembly Instruction FVM2...
Page 26
M-COM LECTRIC CONNECTION CONFIGURED WITH Multi-drive operation with M-COM and locking drive - series connection Individual expansion locking drive drive drive drive FVM2 KS 4 KS 4 KS 4 1x M-COM A maximum of three individual polarity M-COM reversal drives and one locking drive in se- ries connection possible.
Page 27
• Set clamping point close to window and ensure to commissioning, operation and maintenance. accessibility. • Ensure expansion possibilities of the drive and the drive cable. • Consider the cable length and the cross sections of the drives supply lines. Assembly Instruction FVM2...
(e.g. SHEV/Natural smoke and heat exhaust ventilators). 14. Check the intactness of warning instructions and labels at the respective drive. 15. Perform a risk assessment in accordance with Machinery Directive 2006 / 42 / EG, if required, e.g. after modifying the machine. Assembly Instruction FVM2...
We reserve the right to change or discontinue products at any time without prior notice. Illustrations are subject to change. Although we take every care to ensure accuracy, we cannot accept liability for the content of this document. Assembly Instruction FVM2...
Basically the General Terms and Conditions of A GmbH apply to all offers, supplies and services. UMÜLLER UTOMATIC The publication of these assembly and commissioning instructions supersedes all previous editions. Assembly Instruction FVM2...