Aumuller FV1 Assembly And Commissioning Instructions

Aumuller FV1 Assembly And Commissioning Instructions

Locking drive for windows

Advertisement

Quick Links

Assembly and Commissioning
Instructions
according to Machinery Directive 2006 / 42 / EC (annex VI)
FV1 / FV3 / FV4 - L
ocking driVe For windows

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the FV1 and is the answer not in the manual?

Questions and answers

Summary of Contents for Aumuller FV1

  • Page 1 Assembly and Commissioning Instructions according to Machinery Directive 2006 / 42 / EC (annex VI) FV1 / FV3 / FV4 - L ocking driVe For windows...
  • Page 2 Abbreviations Target Groups Warning and Safety Symbols Intended Use 3 - 8 Safety Instructions Data sheet FV1 / FV3 / FV4 Explanations on the product labe 9 - 10 Determination of locking points Inspection before the installation nstallatIon step Installation prerequisite and Installation preparation...
  • Page 3: Target Group

    Children should be supervised to ensure that they are not playing with this device. Cleaning and operator’s maintenance may not be performed by children with- out supervision. Assembly Instruction FV1 / FV3 / FV4...
  • Page 4: Ntended Use

    Pay attention to possible hazards on 103/2016-05. tilting or rotating windows, whose secondary closing edges are located arning at less than 2,5 m installation height ab- ove the fl oor, under consideration of the Control Unit and usage! Assembly Instruction FV1 / FV3 / FV4...
  • Page 5: P Reliminary Remark

    • casement size (FAB x FAH), Opening direction: inward opening, outward opening. • driving force and stroke, Profile material: aluminum, steel, plastic or wood. • mounting site at the window frame and casement frame. Assembly Instruction FV1 / FV3 / FV4...
  • Page 6: Safety Instructions

    Danger spots by crush and shear points Side-hung Bottom-hung Roof windows / skyskylight domes Louvre windows Danger spots: crush and shear points according to DIN EN 60335-2-103 Assembly Instruction FV1 / FV3 / FV4...
  • Page 7 Clamping points shall be checked for tightness of threa- All relevant national instructions shall be observed for ded connections and cable ends. Access to junction boxes, the installation. clamping points and external drive control boxes shall be ensured for maintenance work. Assembly Instruction FV1 / FV3 / FV4...
  • Page 8: Ambient Conditions

    Do not actuate the drive or the case- ment when repair or re-setting works are arning performed! Assembly Instruction FV1 / FV3 / FV4...
  • Page 9: Data Sheet

    ~ 600 N Runtime ~ 5,0 s Connecting cable FV1: non-halogen, grey 2 x 0,75 mm², ~ 3 m FV3: non-halogen, grey 2 x 0,75 mm², ~ 3 m FV4: non-halogen, grey 3 x 0,50 mm², ~ 3 m Housing...
  • Page 10 Art.-Nr.: xxxxxx products. symbols see serial number „Technical data“ In the event of any complaints, please indicate the article reference product serial number (SN) (see product label). date of manufacturing number with firmware version Assembly Instruction FV1 / FV3 / FV4...
  • Page 11: Tools Required

    The requirements for the tightness of the • hexagonal wrench, windows according to EN 14359-1 must • torque wrench, be observed! • power drill, • threadlock adhesive, • possibly a tool for blind rivet nuts. Assembly Instruction FV1 / FV3 / FV4...
  • Page 12: I Nstallation Step

    If this is not guaranteed another type of fastening or another type of drive must be selected. Assembly Instruction FV1 / FV3 / FV4...
  • Page 13 For drives with internal load dependent cut-off switch S3 / S12. F = Drive force • Star wiring. Sequence control via communication wire. s = Stroke Current of the drives does not run over FV4. Assembly Instruction FV1 / FV3 / FV4...
  • Page 14 FV3 (see chapter: „E lEctric 12“). connEction nstallation stEP During start-up of locking drives FV3 the 24 V-control voltage may be switched on only: • with opened casement • unhinged opening drive Assembly Instruction FV1 / FV3 / FV4...
  • Page 15 Top-hung outward opening Top-hung outward opening Frame assembly Frame assembly Frame assembly 35 reference edge 35 35 reference edge reference edge View on PVC window View on aluminium window View on aluminium window Assembly Instruction FV1 / FV3 / FV4...
  • Page 16 Drive Frame assembly - inward opening windows - hole layout FV1 / FV3 / FV4 - single, right-hand, length = 420 mm Window Bottom-hung - inward opening Horizontal + See: versions Top-hung - inward opening vertical pivot...
  • Page 17 Drive Frame assembly - inward opening windows - hole layout FV1 / FV3 / FV4 - double, length = 2000 mm Window Bottom-hung - inward opening Horizontal + See: versions Top-hung - inward opening vertical pivot...
  • Page 18 Drive Frame assembly - outward opening windows - hole layout FV1 / FV3 / FV4 - single, right-hand, length = 420 mm Window Bottom-hung - outward opening Horizontal + See: versions Top-hung - outward opening vertical pivot...
  • Page 19 Drive Frame assembly - outward opening windows - hole layout FV1 / FV3 / FV4 - double, length = 2000 mm Window Bottom-hung - outward opening Horizontal + See: versions Top-hung - outward opening vertical pivot...
  • Page 20 Use screwdriver to pierce the closed drill hole. Remove Remove connection cable (AK) for easier handling. the burrs. Possibly slightly enlarge drill hole. „ Feeding the cable through the new hole carefully.  Provide strain relief Assembly Instruction FV1 / FV3 / FV4...
  • Page 21 : fv1 / fv3 / fv4 ssembly : FV1 / FV3 / FV4 F nstallatIon step rame assembLy inward opening windows „ Screw locking drive FVx onto casement frame (M5) Make sure they are parallel to casement edge. - if necessary with base plate.
  • Page 22 : fv1 / fv3 / fv4 ssembly :F V1 / FV3 / FV4 F nstallatIon step rame assembLy outward opening windows Assembly variant 1:  „ Screw mounting plate for the locking drive FVx onto window frame (M5). Locking angle B18 with adapter plate B22 (optional) ...
  • Page 23 : fv1 / fv3 / fv4 ssembly Assembly: locking drive  Locking bracket „ Screw locking drive FVx on mounting plate (M5). 1x locking pin 1x screw M6 x 10 1x washer „ Connect the connecting cable (AK) to terminal strip 1x pin holder (see chapter „c...
  • Page 24: Dip-S Chalter

    / or an ) The connection of the opening drive is dependent on the opening direction electronic overload disconnection. of the casement CLOSE (locked) Terminal strip OPEN (unlock) Terminal strip Factory settings Assembly Instruction FV1 / FV3 / FV4...
  • Page 25 Opening Locking drive drive When subsequent programming with UniPC Close the same assembly steps as in the installation 24V DC must be carried out with preprogrammed set (see separate: Installation Instructions for UniPC). Assembly Instruction FV1 / FV3 / FV4...
  • Page 26: Cable Routing

    Connection cable routing on the hinge side: • Make sure that during opening or closing procedure the cable will not be damaged by shearing-off, kinking, crushing. • Protect cable feedthrough in profile e.g. by using cable bushings, cable transitions. Assembly Instruction FV1 / FV3 / FV4...
  • Page 27 The programming of the drives in multi-drive occurs at factory or on site with UniPC is used for communication, with synchronized multi-drive operation. WH wires connect, otherwise no function. Optional: 1 to 4 drives and max. 2 locking drives are possible. Assembly Instruction FV1 / FV3 / FV4...
  • Page 28: Electric Connection

    SHEVS applications require a line monitoring Disconnection and sequential control for the locking (line end module) to be connected upstream drive FV1 is provided by the controll module USKM. of the last or the only locking drive FV1! - FV3...
  • Page 29 In composite can be used to four individual drives and two locking drives. locking drive Configuration is done by M-COM. junction box BN = brown site-supplied BU = blue WH = white Assembly Instruction FV1 / FV3 / FV4...
  • Page 30 Rated current per drive: max. 2,5 A Equipment: with cable gland (grey) including strain relief, Drive type: S1, S2, S3, S12, MP, FV1, OFV1 with 2 loose ceramic terminals Protection rating: IP 54 (bipolar). Ambient temperature range: 0 °C ... +70 °C Surf.
  • Page 31 • Set clamping point close to window and ensure accessibility. • Ensure expansion possibilities of the drive and the drive cable. • Consider the cable length and the cross sections of the drives supply lines. Assembly Instruction FV1 / FV3 / FV4...
  • Page 32: Maintenance

    14. Check the intactness of warning instructions and labels at the respective drive. 15. Perform a risk assessment in accordance with Machinery Directive 2006 / 42 / EG, if required, e.g. after modifying the machine. Assembly Instruction FV1 / FV3 / FV4...
  • Page 33: D Isposal / W Arranty

    We reserve the right to change or discontinue products at any time without prior notice. Illustrations are subject to change. Although we take every care to ensure accuracy, we cannot accept liability for the content of this document. Assembly Instruction FV1 / FV3 / FV4...
  • Page 34 Assembly Instruction FV1 / FV3 / FV4...
  • Page 35 Basically the General Terms and Conditions of a GmbH apply to all offers, supplies and services. umüller utomatIc The publication of these assembly and commissioning instructions supersedes all previous editions. Assembly Instruction FV1 / FV3 / FV4...
  • Page 36 9000018401_V2.0_KW21/22...

This manual is also suitable for:

Fv3Fv4

Table of Contents