This is setting can be set only whuen all the following conditions are met:
• The remote controller is powered OFF.
• Weekly timer is not set.
• Weekly timer is not being edited.
(1) Hod down
button on the remote controller for 2 seconds to enter the pairing mode.
(2) Press
button again and assign a number to each remote controller.
(3) Each press of
button advances the number in the following order: 1 2 3 4.
(4) Press
button to complete the pairing setting.
After you turn the breaker ON, the remote controller that first sends a signal to an indoor unit will be
regarded as the remote controller for the indoor unit.
Once they are set, the indoor unit will only receive the signal from the assigned remote controller
afterwards.
(1) Turn the breaker OFF for the unit.
(2) With the remote controller powered OFF, hold down UNIT button on the remote controller for 2
seconds to enter the pairing mode.
(3) Press UNIT button again and assign a number to each remote controller: Each press of UNIT button
advances the number in the following order: 1 2 3 4
(4) Press to OPERATION SELECT (MODE) button complete the pairing setting.
(1) Take out the batteries.
(2) Cut jumpers JR2 - JR4 on the PC board as shown in the tab.
(3) Keeping OFF the remote controller, press
indoor unit number appear.
(4) Set the number as shown in tab. pressing
visualized.
(5) Press
to confirm, the remote controller will shoutdown.
(1) Take out the batteries.
(2) Cut jumpers JR1 - JR2 on the PC board as shown in the tab.
(3) Keeping OFF the remote controller, press
indoor unit number appear.
(4) Set the number as shown in tab. pressing
visualized.
(5) Press
to confirm, the remote controller will shoutdown.
for 2 seconds, until the
, until the right number is
For MSZ-HJ model
for 2 seconds, until the
, until the right number is
For MSZ-DM model
Nr.
J2
J4
0
No Modification
No Modification
1
Solder J2
No Modification
2
No Modification
Solder J4
3-9
Solder J2
Solder J4
Nr.
J1
J2
0
No Modification
No Modification
1
Solder J1
No Modification
2
No Modification
Solder J2
3-9
Solder J1
Solder J2
Nr.
J1
J2
0
No Modification
No Modification
1
Cut J1
No Modification
2
No Modification
Solder J2
3-9
Cut J1
Solder J2

Advertisement