Download Print this page

Mitsubishi Electric M Series Installation Manual page 47

Hide thumbs Also See for M Series:

Advertisement

SUZ-KA/PUHZ-P
S/P SERIES - OUTDOOR UNIT - Standard Inverter
230V
Three-phase connection
DIAMETER
SIZE
MODEL
Liquid mm
(inches)
35
6,35 (1/4")
50
6,35 (1/4")
SUZ-KA
60
6,35 (1/4")
71
9,52 (3/8")
100
9,52 (3/8")
125
PUHZ-P
9,52 (3/8")
140
9,52 (3/8")
Exemple of total additional charge calculation
Formula
Precharge lenght (m)] x additional charge (g/m)
Example
Outdoor unit = SUZ-KA50VA6
Total pipes lenght (inlet piping only) = 30 m
Lenght with additional charge (as tab) = 7 m
Additional charge= 20 g/m
Calculation: ∆W(g) = [30 - 7] x 20 = 460 g
L
N
Breaker
SUZ-KA/PUHZ-P
L1
L2
380V
L3
N
Breaker
EXTERNAL PIPING
Gas mm
Max
Max
(inches)
Height
Lenght*
9,52 (3/8")
12
20
12,7 (1/2")
30
30
15,88 (5/8")
30
30
15,88 (5/8")
30
30
15,88 (5/8")
30
50
15,88 (5/8")
30
50
15,88 (5/8")
30
50
∆W(g) = [Lenght of pipes (m) -
S1
S2
S3
REFRIGERANT CHARGE
Precharge
Max
Precharge
lenght
Pipe Bends
Kg*
mt.
10
1,15
10
1,60
7
10
1,60
10
1,80
15
3,30
15
3,80
30
15
3,80
MITSUBISHI ELECTRIC / P SERIES R410A
S1
S2
S3
Indoor unit
Additional
tonCO
eq
tonCO
eq
charge
2
2
precharge*
max charge*
g/mt
30
2,40
1,04
20
3,34
1,39
55
3,34
2,19
3,76
2,15
6,89
3,04
60
7,93
4,59
7,93
4,59
R410A
ELECTRICAL DATA
Operating
current
Breaker
max
1
10 A
1
20 A
1
20 A
1
20 A
1 / 3
32 A / 16 A
1 / 3
32 A / 16 A
1 / 3
40 A / 16 A
45

Advertisement

loading