Download Print this page

Mitsubishi Electric M Series Installation Manual page 11

Hide thumbs Also See for M Series:

Advertisement

MSZ-HR
M SERIES - WALL MOUNTED UNIT - DC Inverter/Heat Pump
230V
Breaker
DIAMETER
SIZE
Liquid mm
Gas mm
(inches)
(inches)
25
6,35 (1/4")
9,52 (3/8")
35
6,35 (1/4")
9,52 (3/8")
42
6,35 (1/4")
9,52 (3/8")
50
6,35 (1/4")
9,52 (3/8")
60
6,35 (1/4")
12,7 (1/2")
71
6,35 (1/4")
12,7 (1/2")
Example of total additional charge calculation
Formula
Precharge lenght (m)] x additional charge (g/m)
Example
Indoor/Outdoor unit = MSZ-HR25VF / MUZ-HR25VF
Total pipes lenght (inlet piping only) = 10 m
Lenght with additional charge (as tab) = 7 m
Additional charge = 20 g/m
Calculation: ∆W(g) = [10 - 7] x 20 = 60 g
L
N
MUZ-HR_VF
EXTERNAL PIPING
Max
Max
Max
Height
Lenght*
Pipe Bends
12
20
10
12
20
10
12
20
10
12
20
10
15
30
10
15
30
10
∆W(g) = [Lenght of pipes (m) -
S1
S2
S3
REFRIGERANT CHARGE
Precharge
Additional
Precharge
lenght
charge
Kg*
mt.
g/mt
0,40
0,45
0,70
7
20
0,80
1,05
1,05
MITSUBISHI ELECTRIC / M SERIES
S1
S2
S3
MSZ-HR_VF
ELECTRICAL DATA
Operating
tonCO
eq
tonCO
eq
current
2
2
precharge*
max charge*
max
0,270
0,446
5,0 A
0,304
0,479
6,7 A
0,473
0,648
8,5 A
0,540
0,716
10,0 A
0,709
1,019
13,6 A
0,709
1,019
13,6 A
Breaker
10 A
10 A
10 A
12 A
16 A
16 A
9

Advertisement

loading