Download Print this page

Mitsubishi Electric M Series Installation Manual page 89

Hide thumbs Also See for M Series:

Advertisement

MAC-334IF
Input signals
M-Net2 M-Net1
B2 A2 B1
A1
S
TB520
TB521
SW500
1
2
3
4
5
6
7
8
SW502
1
2
3
4
5
6
7
8
(M-Net)
(Red)
(Orange)
MA
SW580
LE501
LE502
SW501 SW510
No.
FUNCTIONS
ON/OFF
Manual operation
1
prohibited/allowed
(Level contact)
ON/OFF
Manual operation
2
prohibited/allowed
(Pulse contact)
ON/OFF
Remote operation/
3
Manual operation
(Level contact)
ON, OFF
4
(Pulse contact)
Heating/cooling input
5
(Level contact)
No.
FUNCTIONS
Behavior when
6
operation is prohibited
Behavior when
7
prohibition of operation
is canceled
R1
R2
C
-
+
B
A
TB580
TB571
TB530
(Grey)
(Sky Blue)
CN591
(Orange)
(White)
3 2 1
LE581
CN560
(White)
MAC-334IF-E
SW No.
SW500
1
2
3
4
5
6
7
8
SW502
1
2
3
4
5
6
7
8
SW500
1
2
3
4
5
6
7
8
SW502
1
2
3
4
5
6
7
8
SW500
1
2
3
4
5
6
7
8
SW502
1
2
3
4
5
6
7
8
SW500
1
2
3
4
5
6
7
8
SW502
1
2
3
4
5
6
7
8
SW500
1
2
3
4
5
6
7
8
SW502
1
2
3
4
5
6
7
8
SW No.
ON
SW502
1
2
3
4
5
6
7
8
OFF
ON
SW502
1
2
3
4
5
6
7
8
OFF
C
Cable type
Microphone type
Nr. of Conductors
2
Section diameter
0,75 mm o sup.
Max lenght
100 m
1 brown
Switch 1
2 red
Switch 2
3 orange
C
Brown
1
Red
2
Orange
3
CN591
Brown
1
Red
2
Orange
3
CN591
Brown
1
Red
2
Orange
3
CN591
Brown
1
Red
2
Orange
3
CN591
Brown
1
Red
2
Orange
3
CN591
How to use
SW502-5: OFF
Operational status of room air
• When manual operations are prohibited using Switch 2, the operating
conditioner when manual
status remains that prior to the prohibition of manual operations.
operation is prohibited can
SW502-5: ON
be set
• When manual operations are prohibited using Switch 2,
air conditioner turns off.
SW502-6: OFF
Operational status of room air
• When the prohibition of manual operations is canceled using
conditioner when prohibition of
Switch 2, the operating state remains the one before the cancellation.
manual operation is canceled
SW502-6: ON
can be set
• When the prohibition of manual operations is canceled using Switch
2, the room air conditioner turns on.
MITSUBISHI ELECTRIC / OPTIONAL PARTS
SW500
1
1
2
2
SW502
3
CN591
1
2
Card Key/Coin timer connection
SW500
1
1
2
2
SW502
3
CN591
1
2
ON/OFF switch connection
How to use
Switch 1:
ON/OFF
Switch 2:
Manual operation
prohibited/allowed
Switch 1:
ON/OFF
Switch 2:
Manual operation
prohibited/allowed
Switch 1:
ON/OFF
Switch 2:
Remote operation/
Manual operation
Switch 1:
ON
Switch 2:
OFF
Switch 1:
ON/OFF
Switch 2:
Heating/cooling
Operational details
3
4
5
6
7
8
3
4
5
6
7
8
3
4
5
6
7
8
3
4
5
6
7
8
87

Advertisement

loading