Download Print this page

Mitsubishi Electric M Series Installation Manual page 13

Hide thumbs Also See for M Series:

Advertisement

MSZ-HJ
M SERIES - WALL MOUNTED - DC Inverter/Heat Pump
230V
Breaker
DIAMETER
SIZE
Liquid mm
Gas mm
(inches)
(inches)
25
6,35 (1/4")
9,52 (3/8")
35
6,35 (1/4")
9,52 (3/8")
50
6,35 (1/4")
12,7 (1/2")
60
6,35 (1/4")
15,88 (5/8")
71
6,35 (1/4")
15,88 (5/8")
L
N
MSZ-HJ_VA
EXTERNAL PIPING
Max
Max
Max
Precharge
Height
Lenght
Pipe Bends
12
20
10
0,70
12
20
10
0,72
12
20
10
1,15
15
30
10
1,80
15
30
10
S1
S2
S3
REFRIGERANT CHARGE
Precharge
Additional
lenght
charge
Kg
mt.
g/mt
7
20
1,80
MITSUBISHI ELECTRIC / M SERIES
S1
S2
S3
MUZ-HJ_VA
ELECTRICAL DATA
Operating
tonCO
eq
tonCO
eq
current
2
2
precharge
max charge*
max
1,462
2,004
5,8 A
1,503
2,046
6,5 A
2,401
2,944
9,8 A
3,758
4,719
12,5 A
3,758
4,719
12,5 A
R410A
Breaker
10 A
10 A
12 A
16 A
16 A
11