  • Page 1 Your Global Automation Partner TN…-IOL2… HF Read/Write Heads Instructions for Use...
  • Page 2 Hans Turck GmbH & Co. KG | T +49 208 4952-0 | F +49 208 4952-264 | more@turck.com | www.turck.com...
  • Page 3: Table Of Contents

    Feedback about these instructions................ 5 Notes on the Product .........................  6 Product identification.....................  6 Scope of delivery ...................... 6 Legal requirements...................... 6 Turck service........................ 6 For Your Safety............................  7 Intended use........................ 7 General safety notes .......................  7 Product Description ...........................  8 Device overview ......................
  • Page 4 11 Maintenance............................ 32 12 Repair.............................. 32 12.1 Returning devices...................... 32 13 Disposal .............................. 32 14 Technical Data........................... 33 15 Turck Subsidiaries - Contact Information .................. 34 Hans Turck GmbH & Co. KG | T +49 208 4952-0 | F +49 208 4952-264 | more@turck.com | www.turck.com...
  • Page 5: About These Instructions

    This symbol denotes actions that the user must carry out. RESULTS OF ACTION This symbol denotes relevant results of actions. Other documents Besides this document the following material can be found on the Internet at www.turck.com: Data sheet IO-Link parameters manual Commissioning manual IO-Link devices...
  • Page 6: Notes On The Product

    CAD files in numerous export formats. The contact details of Turck subsidiaries worldwide can be found on p. [} 34]. Hans Turck GmbH & Co. KG | T +49 208 4952-0 | F +49 208 4952-264 | more@turck.com | www.turck.com...
  • Page 7: For Your Safety

    The product is designed according to state-of-the-art technology. However, residual risks still exist. Observe the following warnings and safety notices to prevent damage to persons and property. Turck accepts no liability for damage caused by failure to observe these warning and safety notices.
  • Page 8: Product Description

    Password function for accessing the tag (separate hardware must be used to activate the password function) Operating hours counter Male connector, M12 × 1, 4-pin Hans Turck GmbH & Co. KG | T +49 208 4952-0 | F +49 208 4952-264 | more@turck.com | www.turck.com...
  • Page 9: Functional Principle

    The size of the transmission window depends on the combination of read/write heads and tags. Each Turck read/write head can communicate with a number of Turck tags. This requires the read/write head and the tag to operate in the same frequency range. Depending on the power and frequency used, the device ranges vary from a few millimeters up to several meters.
  • Page 10: Io-Link Mode

    Accessories for mounting, connecting and parameterizing can be found in product database under www.turck.com. The accessories are not part of the scope of delivery. Hans Turck GmbH & Co. KG | T +49 208 4952-0 | F +49 208 4952-264 | more@turck.com | www.turck.com...
  • Page 11: Installing

    Installing Installing cylindrical devices The maximum tightening torque of the housing nut is 25 Nm (M18 design) and 70 Nm (M30 design). „ Install the device with the appropriate fixing accessories so that the front cap of the devices fully protrudes from the surrounding area. „...
  • Page 12: Installing Rectangular Devices

    „ Protect the device from heat radiation, rapid temperature fluctuations, severe contamin- ation, electrostatic charge and mechanical damage. Hans Turck GmbH & Co. KG | T +49 208 4952-0 | F +49 208 4952-264 | more@turck.com | www.turck.com...
  • Page 13: Connection

    Connection „ Connect the open end of the connecting cable (e.g. RKC4.4T-2/TXL, ID 6625503) to an IO- Link master. „ Connect the connecting cable coupling to the connector at the rear of the device. Wiring diagram Pin assignment Wiring diagram Description 1 BN L+ 24 VDC 1 BN...
  • Page 14: Commissioning

    In SIO mode, the functions relating to data synchronization and tag presence are available. For more information on setting up the functions, refer to the IO-Link parameters manual. Hans Turck GmbH & Co. KG | T +49 208 4952-0 | F +49 208 4952-264 | more@turck.com | www.turck.com...
  • Page 15: Setting And Parameterization

    The read/write heads can be set and configured via IO-Link function blocks. The function blocks for the CODESYS V3 and Siemens TIA V14 programming environments are available as free downloads from www.turck.com. Further information on programming the function blocks is provided in the description of the process data.
  • Page 16 Setting Setting with IO-Link function block Function block for TIA-Portal V14 Fig. 8: Function block for TIA-Portal V14 Hans Turck GmbH & Co. KG | T +49 208 4952-0 | F +49 208 4952-264 | more@turck.com | www.turck.com...
  • Page 17: Io-Link Mode - Process Data

    IO-Link mode – process data 8.3.1 IO-Link mode – process input data Byte no. CMDCOPY ERROR CODE ALR1 ALR2 RSSI ADDRESS 4…31 DATA 0…27 or UID7…0, STTI7…0, TIRT7…0 Meaning of the status bits Designation Meaning Ò Ò 0 or 0 1: Command executed, new data available 0 or 1: No new data available 0: Command executed error-free...
  • Page 18: Io-Link Mode - Process Output Data

    FRAM: 8 bytes per block The device does not output an error message if more than 28 bytes of write data are specified. Hans Turck GmbH & Co. KG | T +49 208 4952-0 | F +49 208 4952-264 | more@turck.com | www.turck.com...
  • Page 19: Process Data - Error Codes

    8.3.3 Process data – error codes Error code Error code Name Description (dec.) (hex.) 0x01 CommandNotSupported Tag error in accordance with ISO 15693 (depending on the sup- 0x02 FormatError ported command set of the used tag) 0x03 OptionNotSupported 0x05 CommandProblem 0x06 CommTagError 0x0F TagError...
  • Page 20: Operation

    Tag at the limit of the detection range (5 Hz) Q2/BUSY Yellow flashing Command is executed (1 Hz) ERROR Error detected POWER Green flashing IO-Link mode active (1 Hz) Hans Turck GmbH & Co. KG | T +49 208 4952-0 | F +49 208 4952-264 | more@turck.com | www.turck.com...
  • Page 21: Led Indication - Sio Mode

    9.1.2 LED indication – SIO mode Indication Meaning Q1/TAG Yellow Output 1 active Yellow flashing Output 1: Tag in the Data update or Tag presence operating (5 Hz) modes at the limit of the detection range Q2/BUSY Yellow Output 2 active Yellow flashing Output 2: Tag in the Data update or Tag presence operating (1 Hz)
  • Page 22: Rfid Commands - Flow Charts

    CMD = 0 Inventory Tag detected RSSI value is reported by the device. TAG LED Power off (IO-Link) Fig. 11: Idle Hans Turck GmbH & Co. KG | T +49 208 4952-0 | F +49 208 4952-264 | more@turck.com | www.turck.com...
  • Page 23: Auto Read

    9.3.3 Auto read With an automatic read, the device automatically executes a read command as soon as the status of the start bit changes (rising or falling edge). The start bit is automatically switched if a tag enters the detection range. CMD = 1 NB BLOCK: read (Auto Read)
  • Page 24: Auto Write

    RFID data to write? RFID data RFID error: Power off written see error code (IO-Link) successfully. list Fig. 13: Auto write Hans Turck GmbH & Co. KG | T +49 208 4952-0 | F +49 208 4952-264 | more@turck.com | www.turck.com...
  • Page 25: Read

    9.3.5 Read With a read operation, the device automatically executes a read command as soon as the status of the start bit changes (rising or falling edge). The user must manually trigger the switching of the start bit. Proceed as follows to execute the command: „...
  • Page 26 PDI Byte 4…31. *The edge of the ready bit behaves equivalently to the start bit. Fig. 14: Read Hans Turck GmbH & Co. KG | T +49 208 4952-0 | F +49 208 4952-264 | more@turck.com | www.turck.com...
  • Page 27: Write

    9.3.6 Write With a write operation, the device automatically executes a write command as soon as the status of the start bit changes (rising or falling edge). The user must manually trigger the switching of the start bit. Proceed as follows to execute the command: „...
  • Page 28 (IO-Link) successfully. list *The edge of the ready bit behaves equivalently to the start bit. Fig. 15: Write Hans Turck GmbH & Co. KG | T +49 208 4952-0 | F +49 208 4952-264 | more@turck.com | www.turck.com...
  • Page 29: Querying A Uid And Time Stamp

    9.3.7 Querying a UID and time stamp The device queries the UID and the following time stamps: Time at which tag was detected Time in which the tag is located in the detection range CMD = 5 (UID) present? Tag = true Tag = false TAG LED TAG LED...
  • Page 30: Using The Password Function

    TBEN-RFID interface. Example: The password 01020304 was written to the tag via the TBEN-RFID interface. The entry in the Password parameter is 04030201. Hans Turck GmbH & Co. KG | T +49 208 4952-0 | F +49 208 4952-264 | more@turck.com | www.turck.com...
  • Page 31: Troubleshooting

    Troubleshooting If the device does not function as expected, first check whether ambient interference is present. If there is no ambient interference present, check the connections of the device for faults. If there are no faults, there is a device malfunction. In this case, decommission the device and replace it with a new device of the same type.
  • Page 32: Maintenance

    Disposal The devices must be disposed of correctly and must not be included in general household garbage. Hans Turck GmbH & Co. KG | T +49 208 4952-0 | F +49 208 4952-264 | more@turck.com | www.turck.com...
  • Page 33: Technical Data

    Technical Data Technical data TN-M18-IOL2-H1141 TN-M30-IOL2-H1141 TN-Q40-IOL2-H1141 100012160 100012162 100012163 Electrical data Operating voltage 11…32 VDC DC rated operational ≤ 50 mA current Inrush current 700 mA for 1 ms Data transfer Inductive coupling Technology HF (13.56 MHz) Operating frequency 13.56 MHz Radio communication ISO 15693...
  • Page 34: Turck Subsidiaries - Contact Information

    Turck Banner Malaysia Sdn Bhd Unit A-23A-08, Tower A, Pinnacle Petaling Jaya, Jalan Utara C, 46200 Petaling Jaya Selangor www.turckbanner.my Hans Turck GmbH & Co. KG | T +49 208 4952-0 | F +49 208 4952-264 | more@turck.com | www.turck.com...
  • Page 35 Mexico Turck Comercial, S. de RL de CV Blvd. Campestre No. 100, Parque Industrial SERVER, C.P. 25350 Arteaga, Coahuila www.turck.com.mx Turck B. V. Netherlands Ruiterlaan 7, NL-8019 BN Zwolle www.turck.nl Austria Turck GmbH Graumanngasse 7/A5-1, A-1150 Wien www.turck.at Poland TURCK sp.z.o.o.
  • Page 36 Over 30 subsidiaries and over 60 representations worldwide! 100021277 | 2021/05 100021277 www.turck.com...