  • Page 1 TX800 HMI/PLC Series Instructions for Use...
  • Page 2: Table Of Contents

    Slot assignment – serial interfaces.................. 19 Commissioning.......................... 20 Charging the battery.................... 20 Using the touchscreen .................... 20 Initial commissioning.................... 20 7.3.1 User management ........................ 21 V01.00 | 2024/03 | 2 Hans Turck GmbH & Co. KG | T +49 208 4952-0 | more@turck.com | www.turck.com...
  • Page 3 13 Disposal..............................  33 14 Technical data...........................  34 15 Appendix: approvals and markings .....................  38 16 Turck branches — contact data .................... 39 V01.00 | 2024/03 | 3 Hans Turck GmbH & Co. KG | T +49 208 4952-0 | more@turck.com | www.turck.com...
  • Page 4: About These Instructions

    If you have any suggestions for improving the design or if some information is missing in the document, please send your suggestions to techdoc@turck.com. V01.00 | 2024/03 | 4 Hans Turck GmbH & Co. KG | T +49 208 4952-0 | more@turck.com | www.turck.com...
  • Page 5: Notes On The Product

    Type designation TX810-… 100046994 Year/week of production A2347 Internal version ID of the product V.: … Serial number S.N.: AA…AA V01.00 | 2024/03 | 5 Hans Turck GmbH & Co. KG | T +49 208 4952-0 | more@turck.com | www.turck.com...
  • Page 6: Type Code

    Connector for serial interface Mounting brackets Quick Start Guide Turck service Turck supports you in your projects – from the initial analysis right through to the commission- ing of your application. The Turck product database at www.turck.com offers you several soft- ware tools for programming, configuring or commissioning, as well as data sheets and CAD files in many export formats.
  • Page 7: For Your Safety

    The product is designed according to state of the art technology. Residual hazards, however, still exist. Observe the following safety instructions and warnings in order to prevent danger to persons and property. Turck accepts no liability for damage caused by failure to observe these safety instructions.
  • Page 8: Conditions Resulting From Ex Approvals For Use In Zone 2/Zone 22

    Care shall be taken not to allow layers of dust to form on the graphic panel in a way that might cause the accumulation of static charges. The devices have only been evaluated for low risk of mechanical impact. V01.00 | 2024/03 | 8 Hans Turck GmbH & Co. KG | T +49 208 4952-0 | more@turck.com | www.turck.com...
  • Page 9: Product Description

    197 mm/7.80” 282 mm/11.10” 56 mm/2.20” TX815 267 mm/10.50” 422 mm/16.60” 56 mm/2.20” TX821 347 mm/13.66” 552 mm/21.73” 56 mm/2.20” V01.00 | 2024/03 | 9 Hans Turck GmbH & Co. KG | T +49 208 4952-0 | more@turck.com | www.turck.com...
  • Page 10: Properties And Features

    Specification Format FAT, FAT32 Max. size Limited by FAT32 specifications ≤ 4 GB for a single file ≤ 32 GB V01.00 | 2024/03 | 10 Hans Turck GmbH & Co. KG | T +49 208 4952-0 | more@turck.com | www.turck.com...
  • Page 11: Accessories

    2.4 GHz and 5 GHz 100010167 TX-DP-S PROFIBUS-DP slave, 12 Mbaud 4.4.2 Power supply Type Description 100002938 TX-PSC TX power supply onnector V01.00 | 2024/03 | 11 Hans Turck GmbH & Co. KG | T +49 208 4952-0 | more@turck.com | www.turck.com...
  • Page 12: Installing

    The minimum tightening torque for the fixing screws of the holding clamps is 130 Ncm. The mounting brackets must rest firmly on the device. V01.00 | 2024/03 | 12 Hans Turck GmbH & Co. KG | T +49 208 4952-0 | more@turck.com | www.turck.com...
  • Page 13: Fasten Devices In The Mounting Cutout

    IP66 is 130 Ncm. Installing plug-in modules Fig. 7: Installing plug-in modules Fig. 8: Installing plug-in modules (e. g. TX-CAN, TX-IO-DX06) (e. g. TX-IO-XX03) V01.00 | 2024/03 | 13 Hans Turck GmbH & Co. KG | T +49 208 4952-0 | more@turck.com | www.turck.com...
  • Page 14: Grounding The Device

    MΩ resistor with 4.7 nF capacitor connected in parallel). „ The power supply must have double or reinforced insulation. Fig. 9: Power supply – wiring V01.00 | 2024/03 | 14 Hans Turck GmbH & Co. KG | T +49 208 4952-0 | more@turck.com | www.turck.com...
  • Page 15: Connecting

    Serial interface Ethernet port 0 (10/100 Mbit) Ethernet port 1 (10/100 Mbit) Expansion slot for plug-in modules SD card slot V01.00 | 2024/03 | 15 Hans Turck GmbH & Co. KG | T +49 208 4952-0 | more@turck.com | www.turck.com...
  • Page 16: Connecting Tx807, Tx810, Tx815 And Tx821

    Default settings of the Ethernet ports ETH0/WAN: DHCP ETH1/LAN: IP address: 192.168.1.254 Subnet mask: 255.255.255.0 ETH2/LAN: DHCP (only for TX807, TX810, TX815 and TX821) V01.00 | 2024/03 | 16 Hans Turck GmbH & Co. KG | T +49 208 4952-0 | more@turck.com | www.turck.com...
  • Page 17: Connecting The Power Supply

    To operate in RS485, pins 1 and 2 as well as pins 3 and 4 must be connected extern- ally. V01.00 | 2024/03 | 17 Hans Turck GmbH & Co. KG | T +49 208 4952-0 | more@turck.com | www.turck.com...
  • Page 18: Connecting Plug-In Modules

    TX815 and TX821 TX-RS232 RS232 Serial TX-IO-DX06 Compact I/O TX-IO-XX03 Multifunction I/O 1 TX805: TX-EXTEND or other extension module necessary V01.00 | 2024/03 | 18 Hans Turck GmbH & Co. KG | T +49 208 4952-0 | more@turck.com | www.turck.com...
  • Page 19: Slot Assignment - Can Port

    Mode COM3 COM Port 3 Slot 1 to Slot 4 refer to the extension slots on the rear of the device. V01.00 | 2024/03 | 19 Hans Turck GmbH & Co. KG | T +49 208 4952-0 | more@turck.com | www.turck.com...
  • Page 20: Commissioning

    IP address is therefore set via the system settings on the touch screen of the device, via a DHCP server in the network, via the Turck Automation Suite (TAS) or via the Turck Service Tool. V01.00 | 2024/03 | 20...
  • Page 21: User Management

    If the simple link causes a conflict with an already active WebVisu application, the system settings can also be accessed directly via the following link: https://IP/machine_config Example access: https://192.168.1.24/machine_config Username: admin Password: admin V01.00 | 2024/03 | 21 Hans Turck GmbH & Co. KG | T +49 208 4952-0 | more@turck.com | www.turck.com...
  • Page 22: Setting The Ip Address

    Set the IP address, the subnet mask, etc. under Network interface and save the changes. Fig. 19: Webserver – network interface V01.00 | 2024/03 | 22 Hans Turck GmbH & Co. KG | T +49 208 4952-0 | more@turck.com | www.turck.com...
  • Page 23: Setting The Ip Address Via Turck Service Tool

    Turck Service Tool shows the connected devices. NOTE Clicking the device's IP address opens the web server. Fig. 21: Turck Service Tool – found devices V01.00 | 2024/03 | 23 Hans Turck GmbH & Co. KG | T +49 208 4952-0 | more@turck.com | www.turck.com...
  • Page 24: Setting The Ip Address Via Tas (Turck Automation Suite)

    Fig. 23: Turck Automation Suite: Scan network The Turck Automation Suite shows the connected devices. Fig. 24: Turck Automation Suite: found devices V01.00 | 2024/03 | 24 Hans Turck GmbH & Co. KG | T +49 208 4952-0 | more@turck.com | www.turck.com...
  • Page 25 Change the IP address and, if necessary, the default gateway and subnet mask in the network settings window. „ Accept the changes with apply. Fig. 25: Turck Automation Suite: Change network settings V01.00 | 2024/03 | 25 Hans Turck GmbH & Co. KG | T +49 208 4952-0 | more@turck.com | www.turck.com...
  • Page 26: Programming With Codesys

    Tap-Tap-Mode [} 28] Ò Startup sequence Ò sign on as „admin” and move CODESYS- App from the Boot Sequence area to Installed Aps. V01.00 | 2024/03 | 26 Hans Turck GmbH & Co. KG | T +49 208 4952-0 | more@turck.com | www.turck.com...
  • Page 27: Transferring Tx Visupro To The Device

    Project transfer via a USB stick „ Create an update package with TX VisuPro and copy it to a USB stick. V01.00 | 2024/03 | 27 Hans Turck GmbH & Co. KG | T +49 208 4952-0 | more@turck.com | www.turck.com...
  • Page 28: Configuring

    In addition to the options in user mode, the system mode includes additional commands for system upgrade and recovery. Device without TX VisuPro runtime Device with software error V01.00 | 2024/03 | 28 Hans Turck GmbH & Co. KG | T +49 208 4952-0 | more@turck.com | www.turck.com...
  • Page 29 Services Activate/deactivate services (e.g. OpenSSH server, bridge, cloud, router, SNMP, logging) V01.00 | 2024/03 | 29 Hans Turck GmbH & Co. KG | T +49 208 4952-0 | more@turck.com | www.turck.com...
  • Page 30 By default, the device is restarted in user mode via the "Main OS" op- tion. The "Configuration OS" option restarts the device directly in Sys- tem Settings in System Mode. V01.00 | 2024/03 | 30 Hans Turck GmbH & Co. KG | T +49 208 4952-0 | more@turck.com | www.turck.com...
  • Page 31: Operating

    LED orange (left LED) Meaning No Ethernet connection Ethernet connection established LED green (right LED) Meaning No data transfer Flashing Data transfer V01.00 | 2024/03 | 31 Hans Turck GmbH & Co. KG | T +49 208 4952-0 | more@turck.com | www.turck.com...
  • Page 32: Troubleshooting

    If there are no faults, there is a device malfunction. In this case, decommission the device and replace it with a new device of the same type. V01.00 | 2024/03 | 32 Hans Turck GmbH & Co. KG | T +49 208 4952-0 | more@turck.com | www.turck.com...
  • Page 33: Maintenance

    Do not use solvents. Repair The device must not be repaired by the user. Take defective devices out of operation and re- turn them to Turck for an error analysis. Observe our return acceptance conditions when re- turning the device to Turck. 12.1...
  • Page 34: Technical Data

    2 × Host V2.0, 2 × Host V2.0, max. 500 mA max. 500 mA max. 500 mA SD card Extension slot (plug-in) V01.00 | 2024/03 | 34 Hans Turck GmbH & Co. KG | T +49 208 4952-0 | more@turck.com | www.turck.com...
  • Page 35 63 kByte Interfaces Ethernet ports 1 × 10/100/1000 Mbit, 1 × 10/100/1000 Mbit, 2 × 10/100 Mbit 2 × 10/100 Mbit V01.00 | 2024/03 | 35 Hans Turck GmbH & Co. KG | T +49 208 4952-0 | more@turck.com | www.turck.com...
  • Page 36 Class A CISPR 22, CISPR 16-2-3 Immunity Electrostatic discharge 8 kV (air electrostatic discharge) EN 61000-4-2 4 kV (contact electrostatic discharge) V01.00 | 2024/03 | 36 Hans Turck GmbH & Co. KG | T +49 208 4952-0 | more@turck.com | www.turck.com...
  • Page 37 Port: DC mains 0 %, duration: 10 ms, 20 fields × 1 s Test executed on the 24Vdc of the EUT EN 61000-4-29 V01.00 | 2024/03 | 37 Hans Turck GmbH & Co. KG | T +49 208 4952-0 | more@turck.com | www.turck.com...
  • Page 38: Appendix: Approvals And Markings

    Declarations of conformity (current version) cULus File No. E484727 File No. E484803 Class I, Division 2, Groups A, B, C and D TAA000027Z V01.00 | 2024/03 | 38 Hans Turck GmbH & Co. KG | T +49 208 4952-0 | more@turck.com | www.turck.com...
  • Page 39: Turck Branches - Contact Data

    Via San Domenico 5, IT-20008 Bareggio (MI) www.turckbanner.it Japan TURCK Japan Corporation ISM Akihabara 1F, 1-24-2, Taito, Taito-ku, 110-0016 Tokyo www.turck.jp V01.00 | 2024/03 | 39 Hans Turck GmbH & Co. KG | T +49 208 4952-0 | more@turck.com | www.turck.com...
  • Page 40 United Kingdom TURCK BANNER LIMITED Blenheim House, Hurricane Way, GB-SS11 8YT Wickford, Essex www.turckbanner.co.uk Turck Inc. 3000 Campus Drive, USA-MN 55441 Minneapolis www.turck.us V01.00 | 2024/03 | 40 Hans Turck GmbH & Co. KG | T +49 208 4952-0 | more@turck.com | www.turck.com...
  • Page 41 Over 30 subsidiaries and 60 representations worldwide! 100048212 | 2024/03 100048212 www.turck.com...