Example Program - Advantech PCE-5130 User Manual

Table of Contents

Advertisement

A.1.3

Example program

1.
Enable watchdog timer and set 10 sec. as timeout interval
;-----------------------------------------------------------
Mov dx,2eh
Mov al,87h
Out dx,al
Out dx,al
;-----------------------------------------------------------
Mov al,07h
Out
dx,al
Inc
dx
Mov
al,08h
Out
dx,al
;-----------------------------------------------------------
Dec dx
Mov
al,30h
Out
dx,al
Inc
dx
Mov
al,01h
Out
dx,al
;-----------------------------------------------------------
Dec dx
Mov
al,0f5h
Out
dx,al
Inc
dx
In
al,dx
And al,not 08h
Out
dx,al
;-----------------------------------------------------------
Dec dx
Mov
al,0f6h
Out
dx,al
Inc
dx
Mov
al,10
Out
dx,al
;-----------------------------------------------------------
Dec dx
Mov
al,0aah
Out
dx,al
2.
Enable watchdog timer and set 5 minutes as timeout interval
;-----------------------------------------------------------
Mov dx,2eh
Mov al,87h
Out dx,al
Out dx,al
PCE-5130 User Manual
; Unlock W83627HF
; Select registers of watchdog timer
; Enable the function of watchdog timer
; Set second as counting unit
; Set timeout interval as 10 seconds and start counting
; Lock W83627HF
; Unlock W83627HF