Page 2
No part of this manual may be reproduced, copied, translated or transmitted in any form or by any means without the prior written permission of Advantech Co., Ltd. Information provided in this manual is intended to be accurate and reliable. How- ever, Advantech Co., Ltd.
Caution! There is a danger of a new battery exploding if it is incorrectly installed. Do not attempt to recharge, force open, or heat the battery. Replace the battery only with the same or equivalent type recommended by the man- ufacturer. Discard used batteries according to the manufacturer's instructions. SOM-5786 User Manual...
Technical Support and Assistance Visit the Advantech web site at www.advantech.com/support where you can find the latest information about the product. Contact your distributor, sales representative, or Advantech's customer service center for technical support if you need additional assistance. Please have the following information ready before you call: –...
Don't touch any components on the CPU card or other cards while the PC is on. Disconnect power before making any configuration changes. The sudden rush of power as you connect a jumper or install a card may damage sensitive elec- tronic components. SOM-5786 User Manual...
Chapter General Information This chapter gives background information on the SOM-5786 CPU System on Module. Sections include: ! Introduction ! Specification...
PCI Express and SATA interfaces. In a basic form factor of 95 mm x 125 mm, the SOM-5786 provides a scal- able high performance and easy to integrate solution for customers’ applications by utilizing a plug-in CPU module on an application-specific customer solution board.
Dual-view supports CRT / LCD displays – Supports 18-bit dual channel LVDS interface Display mode: – CRT Mode: Support up to 2048 x 1536 – LCD Mode: Support up to 1600 x 1200 – TV Mode: Support up to 1024 x 768 SOM-5786 User Manual...
Chapter Mechanical Information This chapter gives mechanical and connector information on the SOM-5786 CPU System on Mod- ule. Sections include: ! Connector Information ! Mechanical Drawing...
Board Connector There are two connectors at the rear side of SOM-5786 for connecting to carrier board. Figure 2.1 SOM-5786 Locating Connectors Pin Assignments for X1/2 connectors Please refer to SOM-Express Design and Specification Guide, Chapter 2. SOM-5786 User Manual...
CPUs from 386 through Pentium and AMD Geode, K7 and K8 (including multiple pro- cessor platforms), and VIA Eden C3 and C7 CPU. You can use Advantech’s utilities to select and install features to suit your customers requirements. BIOS Setup The SOM-5786 system has build-in AwardBIOS with a CMOS SETUP utility which allows users to configure required settings or to activate certain system features.
This setup page includes Load System Optimized for the best performance configuration. Set Password Establish, change or disable a password. Save & Exit Setup Save CMOS value settings to CMOS and exit BIOS setup. Exit Without Saving Abandon all CMOS value changes and exit BIOS setup. SOM-5786 User Manual...
All, But Keyboard The system boot will not stop for a keyboard error; it will stop for all other errors (Default value). All, But Diskette The system boot will not stop for a disk error; it will stop for all other errors. SOM-5786 User Manual...
This item allows user to choose the VIRUS Warning feature for IDE Hard Disk boot sector protection. CPU L3 Cache [Enabled] This item allows user to enable CPU L3 cache. Hyper-Threading Technology [Enabled] This item allows user to enable supported on the Intel® Pentium® 4 Processor with HT Technology. SOM-5786 User Manual...
Page 24
This item sets the operating system multiprocessor support version. OS Select For DRAM > 64 M [Non-OS2] Select OS2 only if system is running OS/2 operation system with greater than 64 MB of RAM on the system. SOM-5786 User Manual...
This item allows the user to select whether onboard graphics processor or the PCI Express card. PEG Force X1 [Disabled] This item allows the user to covert a PCI Express X16 slot to PCI Express X1 slot. On-Chip Frame Buffer Size [8 MB] SOM-5786 User Manual...
Onboard Serial port 1 [3F8/IRQ4] This item allows the user to adjust serial port 1 of address and irq. Onboard Serial port 2 [2F8/IRQ3] This item allows the user to adjust serial port 2 of address and irq. SOM-5786 User Manual...
Page 27
This item allows the user to select system power status after power loss. USB Device Setting This item enables users to set the OnChip USB functions, includes enable USB1.1/2.0 controller and operation mode, and USB keyboard/mouse/storage functions. SOM-5786 User Manual...
V/H SYNC+Blank This option will cause system to turn off vertical and horizontal syn- chronization ports and write blanks to the video buffer. Blank Screen This option only writes blanks to the video buffer. DPMS Initial display power management signaling. SOM-5786 User Manual...
Page 29
This item allows users to enable and key in Date/time to power on system Disabled Disable this function. Enabled Enable alarm function to power on system. Data (of month) Alarm 1-31 Time (HH:MM:SS) Alarm (0-23) : (0-59) : 0-59) SOM-5786 User Manual...
INT Pin 1~8 Assignment [Auto] The interrupt request (IRQ) line assigned to a device connected to the PCI interface on your system. Maximum payload Size [4096] The item allows users to adjust maximum TLP (Transaction Layer Packet) pay- load size. SOM-5786 User Manual...
CPU Temperature [Show Only] This item displays current CPU temperature. Local Temperature [Show Only] This item displays current system temperature. CPU/ 1.8 V DDR2/12 V Input Voltage [Show Only] This item displays current CPU and system Voltage. SOM-5786 User Manual...
Auto Detect PCI Clk [Enabled] This item enables users to set the PCI Clk by system automatic detection or by manual. Spread Spectrum [Disabled] This item enables users to set the spread spectrum modulation. SOM-5786 User Manual...
Load Optimized Defaults loads the default system values directly from ROM. If the stored record created by the Setup program should ever become corrupted (and therefore unusable) these defaults will load automatically when you turn SOM-5786 system on. 3.2.11 Set Password...
Page 34
Select Set Password again, and at the “Enter Password” prompt, please don’t enter anything; just press <Enter>. At the “Confirm Password” prompt, again, don’t type in anything; just press <Enter>. Select Save to CMOS and EXIT, type <Y>, then <Enter>. SOM-5786 User Manual...
Type "Y" will quit the BIOS Setup Utility and save user setup value to CMOS. Type "N" will return to BIOS Setup Utility. 3.2.13 Quit Without Saving Note! Type "Y" will quit the BIOS Setup Utility without saving to CMOS. Type "N" will return to BIOS Setup Utility. SOM-5786 User Manual...
Chapter Driver Installation This chapter gives you the driver installation information on the SOM-5786 CPU System on Module. Sections include: ! Driver Information ! Driver Installation...
Driver Introduction The CD shipped with SOM-5786 should contain below drivers, please follow the below sequence to complete the driver installation. Step 1- Install Intel RAID Disk Driver for Windows XP/2000. (This Step is required to be done before installing Microsoft Windows) Step 2- Install Intel INF Update Driver for Windows XP/2000.
Driver Installation Insert the SOM-5786 CD into the CD-ROM device, and follow the below installation process from Step 1 to Step 5 or 6. 4.2.1 Step 1- Install Intel RAID Disk Driver for Windows XP/2000 To install the Intel RAID Disk Driver, you need to make a utility floppy disk before installing Microsoft Windows on SOM-5786, please make this floppy disk on another Windows based PC.
Click “Start” button and choose the “Control Panel”, Click the “System” Icon. Click the exclamation mark of PCI device. Install the inf file in “Chipset/IT8888” folder. Follow the instructions that the driver installation wizard shows. Then the inf file is installed. SOM-5786 User Manual...
Appendix System Assignments This appendix gives you the infor- mation about the watchdog timer programming on the SOM-5786 CPU System on Module. Sections include: ! Watchdog Timer Programming...
Power-on default [7:0] =0000_0000b Table A.3: Watchdog Timer Range - Index 37h Name Description WD_TIME VSB3V Watchdog timing range from 0 - 255. The unit is either second or minute programmed by the watchdog timer control register bits. SOM-5786 User Manual...
Appendix Programming GPIO This Appendix gives the illustra- tion of the General Purpose Input and Output pin setting. Sections include: ! System I/O ports...
Advantech provides SUSI (Secure&Unified Smart Interface) API for customers. It is a set of user-friendly, intelligent and integrated application programming interfaces, which shortens development time, enhances security and offers add-on value for Advantech platform users. SUSI makes applications easier and simpler to build and operate.
GPIO 21 output control. Set to 1 for output CTRL function. Set to 0 for input function (default). GP20_O VSB3V GPIO 20 output control. Set to 1 for output CTRL function. Set to 0 for input function (default). SOM-5786 User Manual...
Read the GPIO14 data on the pin.. GP13_P VSB3V Read the GPIO13 data on the pin. GP12_P VSB3V Read the GPIO12 data on the pin. GP11_P VSB3V Read the GPIO11 data on the pin. GP10_P VSB3V Read the GPIO10 data on the pin. SOM-5786 User Manual...
Appendix System Assignments This appendix gives you the infor- mation about the system resource allocation on the SOM-5786 CPU System on Module. Sections include: ! System I/O ports ! DMA Channel Assignments ! Interrupt Assignments ! 1st MB Memory Map...
Intel(R) 82566MM Gigabit Network Connection FF00 - FF07 Mobile Intel(R) 965 Express Chipset Family DMA Channel Assignments Table C.2: DMA channel assignments Channel Function Available Available Standard floppy disk controller Available Direct memory access controller Available Available Available SOM-5786 User Manual...
Microsoft UAA Bus Driver for High Definition Audio Intel(R) ICH8 Family USB Universal Host Controller ®C 2830 IRQ 23 Intel(R) ICH8 Family USB2 Enhanced Host Controller - 2836 USB and Ethernet IRQ is automatically set by the system SOM-5786 User Manual...