AT&T AUDIX Voice Power Installation And Maintenance Manual page 145

Table of Contents

Advertisement

405 (TSM_NOSLOT), MAJOR
TSM: No Slot Available for Script <string>
Contact the NSSC or NSAC for assistance.
406 (TSM_NOSCRIPT), MAJOR
TSM: Cannot Find Script <string>; errno = <integer>
TSM failed to open the specified script file. This occurs if the script
file does not exist. The value of the errno indicates the cause
of the error.
Ensure that the script file (.T file) is in directory /vs/trans.
Script needs to be assigned.
Look up the value of errno in Intro(2), Introduction to Section 2
in the UNIX Programmer Reference Manual.
407 (TSM_BADSCRIPT), MAJOR
TSM: Script <string> has Bad Format
The format of the script file (.T file) is invalid. This can occur if the
file is not the output of the tas assembler.
Ensure that the script file (.T file) is the output of the tas
assembler.
Reload the application software if error persists.
408
(TSM_SCRD), MAJOR
TSM: Read Error on Script < string>
A read error occurred while TSM was reading the script file
from disk.
Hang up the telephone and try again several times.
You have UNIX system disk problems. Reboot the system, then
reload the software.
APPENDIX: System Messages
A-11