Instrument : Network Menu - Advantage Engineering Titan Instruction Manual

Table of Contents

Advertisement

Titan Central Chillers
2.
The test will show a blank screen. If any bad pixels or sectors are detected, those
pixels or sectors will be dark. If dark pixels or sectors are indicated, contact the
factory repair or replacement options.
D.
Sensor Display. There are up to 11 sensors the controller monitors.
1.
Select the Sensor Display item from the Utilities Menu to advance to the first
Sensor Display screen.
To Process
Setpoints
Utilities
50°F
Process Setpoint
Software Version
Hi Deviation
Display Test
Lo Deviation
Sensor Display
Low Flow
S e t p o i n t : 50°F
Circulating
Back
Back
Pick
Pick
Go
Go
2.
Scrolling through the Sensor Display reveals data for the sensor.
• To Process ... displayed in Fahrenheit and Celsius
• From Process ... displayed in Fahrenheit and Celsius
• Process Probe Temperature ... displayed in Fahrenheit and Celsius (optional)
• MCU Temperature ... displayed in Fahrenheit and Celsius
• Head Pressure ... displayed in PSI and kPa
• Suction Pressure ... displayed in PSI and kPa
• Process Probe Pressure ... displayed in PSI and kPa
• Board Temperature ... displayed in Fahrenheit and Celsius
• Flow ... display in GPM and dl/min (optional)
• Flow Switch ... indicates on or off (optional)
• Water Make-Up Switch ... indicates on or off (optional)
3.8

INSTRUMENT : NETWORK MENU

A.
Items in the Network menu include Protocol, Address and Baud Rate
Main Menu
To Process
To Process
50°F
50°F
Setpoints
Utilities
Network
Flow
Options
S e t p o i n t : 50°F
S e t p o i n t : 50°F
Machine
Circulating
Circulating
Back
Pick
Go
B.
Protocol: This is the data format for communication between the unit and the host
computer. Available values are SPI CCP, Modbus RTU and CAMAC. SPI is the standard
Society of Plastics Industry, Inc. protocol. CAC is the CAMAC protocol used on older
Milacron machines. Modbus RTU is used in serial communication and is a common serial
communications protocol for industrial equipment.
To Process
Sensor Display
50°F
To Process
52°F ( 10.9°C)
From Process
54°F ( 12.1°C)
S e t p o i n t : 50°F
Process Probe Temp
-39°F (-39.8°C)
Circulating
Sensor Display
To Process
50°F
Process Probe Pressure
44 PSI (301 kPa)
Board Temperature
94°F (34.3°C)
S e t p o i n t : 50°F
Flow
-1 GPM (-19dl/min)
Circulating
Main Menu
To Process
50°F
Setpoints
Utilities
Network
Flow
Options
S e t p o i n t : 50°F
Machine
Circulating
Back
Pick
Go
ADVANTAGE ENGINEERING, INC.
525 East Stop 18 Road Greenwood, Indiana 46142
317-887-0729
Fax: 317-881-1277
Service Department Fax: 317-885-8683
Email: service@AdvantageEngineering.com
To Process
Sensor Display
50°F
MCU Temperature
105°F ( 40.4°C)
Head Pressure
330 PSI (2277 kPa)
S e t p o i n t : 50°F
Suction Pressure
119 PSI (822 kPa)
Circulating
Sensor Display
To Process
50°F
Flow Switch
On ( ow proven)
Water Make-Up Swith
Off
S e t p o i n t : 50°F
Circulating
Network
Protocol
Baud Rate
Address
Back
Pick
Go
Page: 39