Sensitivity is adjusted from the control module located on the
back of the unit near the top of the frame. A potentiometer
located on the control module adjusts the sensitivity gain. LED
indicators on the control module will illuminate when this is
transition occurs. Again: The desired setting on the control
module is two green LED lights on strobing / or steady
(depending on the backing material and the amount of gain
required to create the transition correctly) at the transition
seeing the gap and reading light through the liner material,
then transitioning to only one Green LED On seeing the
label causing the label to stop dispensing.
The label is positioned by physically moving the Gap Sensor
Adjusting the
along the slot on the frame. Loosen the thumb screw and move
Label Position
the sensor along the slot until the leading edge of the label is
on the Peel
presented to the edge of the peel edge.