Electrical Requirements - Field Controls VentCool Tahoe Series Installation Manual

Whole house fan systems
Table of Contents

Advertisement

GRAVITY DAMPER INFORMATION
The VentCool Tahoe Series fan systems include gravity-closed gravity damper doors that are opened by air
pressure created by fan operation. The dampers serve to block entry of air from the attic into the living space, and
are provided with foam sealing and insulating material in the doors to reduce heat transfer from the attic space.
The Ventcool Tahoe Series Whole House Fan Systems
The Ventcool Tahoe Series Whole House Fan Systems
depending on the specifi c model to be installed. Verify which gravity damper size is provided with your sys-
depending on the specifi c model to be installed. Verify which gravity damper size is provided with your sys-
tem prior to beginning installation of the product.
tem prior to beginning installation of the product.

ELECTRICAL REQUIREMENTS

The VentCool PSC Tahoe Series Whole-House Fan Systems require a 115 volt electrical power supply of mini-
mum 15A ampacity and maximum 15 Amp circuit overcurrent protection. We strongly recommend providing
a dedicated circuit for this fan system.
All electrical components, whether included with the VentCool system or supplied by others, must be rated for
the fan system's electrical load requirements; please refer to the VentCool Tahoe Series specifi cations table for
the electrical load requirements of the specifi c model to be installed.
All wiring and connections must be made according to this manual and all applicable electrical
wiring codes and standards. All applicable electrical codes must be followed to the satisfaction of the local
authority having jurisdiction.
VentCool Tahoe Series Whole House Fan Systems are shipped with a pre-wired 20 foot 115VAC power cord
with Nema 5-15P plug and fan control module (FC3JF) prewired and installed on the fan assembly. The fan
assembly directly connects to the Ventcool digital wall control (WTT) system via 50 foot Plug&Play (P&P) cable.
The P&P cable is equipped with RJ12 connectors that plug directly into the fan assembly control module
and backside of the wall control display. The wall control display is mounted in the living space and is used
for fan control (on/off , timer operation or temperature operation) of the whole house fan system. Refer to
INSTALLATION: Wiring & Controls section for wiring and connection diagrams for the Ventcool Tahoe Series
Whole House Fan (Generation 4) product line.
P/N 780104100 07/20 Rev B
have diff erent gravity damper sizes,
have diff erent gravity damper sizes,
page 4 of 20