Download Print this page

Field Controls 46334200 Instruction Sheet

Swg sidewall power venting kit

Advertisement

SWG SIDEWALL POWER VENTING KIT
Installation Specifications For The Following Furnaces
This instruction sheet contains OEM specific information that supercedes the provided instruction
manual where applicable. All field wiring shown in included wiring diagrams are correct regardless
whether the CK-43 or CK-43F is used.
Kit P/N
46205411
46205405
46205407
46205410
46205403
46205408
46205406
46205401
46205413
46205402
46205409
46205404
Certified As A Component Part of The Furnace Application.
Furnace Manufacturer
Amana Refrigeration Inc.
American Standard Inc. & The Trane Co.
Armstrong Air Conditioning Inc.
Bard Manufacturing Co.
Carrier Corp.
Consolidated Industries Corp.
Dunkirk Radiator Corp.
Evcon Industries Inc.
International Comfort Products (Adjustable)
International Comfort Products (Fixed)
Lennox International Inc.
Rheem Air Conditioning
York International Corp.
Field Controls, L.L.C., 2630 Airport Road, Kinston, NC 28504
Technical Support (800) 742-8368
Contents
Page
2
4
6
7
8
10
11
13
14
16
17
18
19

Advertisement

loading

Summary of Contents for Field Controls 46334200

  • Page 1 Dunkirk Radiator Corp. Evcon Industries Inc. 46205401 International Comfort Products (Adjustable) 46205413 International Comfort Products (Fixed) 46205402 Lennox International Inc. 46205409 Rheem Air Conditioning 46205404 York International Corp. Field Controls, L.L.C., 2630 Airport Road, Kinston, NC 28504 Technical Support (800) 742-8368...
  • Page 2 SWG-4AM AMANA SIDEWALL POWER VENTING KIT Field Controls P/N 46205411 Kit Includes: SWGII-4HD Sidewall Power Venter CK-43 Control Kit Includes: 4" MG-1 Barometric Draft Control Fan Proving Switch Adjustable Post Purge Recommended For Use On The Following Amana Model Furnaces:...
  • Page 3 3" to 4" 60,000 4" None 80,000 4" None 100,000 4" None 120,000 4" None 140,000 4" None General Wiring For complete installation information refer to the Field Controls SWG-4AM Power Venter Installation Manual for details (P/N 46333300.) Page 3...
  • Page 4 Refer to the Diagrams on the following page for guidance in wiring the Power Venter and Control Kit to the appliance. For complete installation information refer to the Field Controls SWG-4AT Power Venter Installation Manual for details (P/N 46306700.) Page 4...
  • Page 5 Page 5...
  • Page 6 Length (ft.); 4" Diameter (in.) Vent Pipe AMEG6G Upflow EG5G Lowboy EG6G Upflow EG7G Downflow EG8G Horizontal Downflow-Horizontal Upflow-Horizontal Upflow General Wiring For complete installation information refer to the Field Controls SWG-4A Power Venter Installation Manual for details (P/N 46333500.) Page 6...
  • Page 7 SWG-4B BARD SIDEWALL POWER VENTING KIT Field Controls P/N 46205410 Kit Includes: SWGII-4HD Sidewall Power Venter CK-43F Control Kit Includes: 4" MG-1 Barometric Draft Control Fan Proving Switch Fixed post purge For Use With The Following Bard Standard Furnaces: Upflow...
  • Page 8 SWGII-4CC CARRIER SIDEWALL POWER VENTING KIT Field Controls P/N 46205403, Carrier P/N KGASW03012SP Kit Includes: SWGII-4HD Sidewall Power Venter CK-43CC Control Kit Includes: 4" MG-1 Barometric Draft Control Fan Proving Switch Fixed post purge For Use With The Following Carrier Furnace Models:...
  • Page 9 See Equivalent Length Table II. Fewer elbows permit longer straight length & vice-versa. ‡ 3"-to-4" increaser is required between vent pipe and power venter. General Wiring: For complete installation information refer to the Field Controls SWGII-4CC Power Venter Installation Manual for details (P/N 46295100.) Page 9...
  • Page 10: Sidewall Power Venting Kit

    SWG-4CD CONSOLIDATED SIDEWALL POWER VENTING KIT Field Controls P/N 46205408 Kit Includes: SWGII-4HD Sidewall Power Venter WMO-1 Thermal Safety Switch (Must be purchased separately if using other venting kit on Consolidated Furnaces.) CK-43F Control Kit Includes: 4" MG-1 Barometric Draft Control...
  • Page 11 The SWG-4CD power venter kit must be installed using type B-1 vent pipe only! General Wiring For complete installation information refer to the Field Controls SWG-4CD Power Venter Installation Manual for details (P/N 46333600.) SWG-4D DUNKIRK SIDEWALL POWER VENTING KIT...
  • Page 12 3” x 90° elbow - reduce vent length by 3 feet for each elbow Standard 3" single walled galvanized venting or 3" Type B vent pipe should be used. Draft Control Installation: Install a 3" vent pipe tee of the same material as the vent piping 12" to 24" away from the outlet of the boiler's blower.
  • Page 13 General Wiring For complete installation information refer to the Field Controls SWG-4D,5D Power Venter Installation Manual for details (P/N 46298400.) SWG-4E EVCON SIDEWALL POWER VENTING KIT Field Controls Standard Model SWGII-4HD and CK-43F Kit Includes: SWGII-4HD Sidewall Power Venter CK-43F Control Kit Includes: 4"...
  • Page 14 General Wiring: For complete installation information refer to the Standard Field Controls SWG/SWGII series Power Venter Installation Manual (P/N 46139100), and the CK-43F Control Kit Installation Manual (P/N 46285100) for details. SWG-4IC INTER-CITY SIDEWALL POWER VENTING KIT Field Controls P/N 46205401...
  • Page 15 Minimum Pipe Length - (1) 90° Elbow, 5 feet of vent pipe and a reducer or increaser if required. General Wiring For complete installation information refer to the Field Controls SWG-4IC Power Venter Installation Manual for details (P/N 46201400.) Page 15...
  • Page 16 Diameter 50,000 3" 3" TO 4" 75,000 4" None Required 100,000 4" None Required 125,000 4" None Required General Wiring For complete installation information refer to the Field Controls SWG-4ICF Power Venter Installation Manual for details (P/N 46319700.) Page 16...
  • Page 17 SWG-4L LENNOX SIDEWALL POWER VENTING KIT Field Controls P/N 46205402 Kit Includes: SWGII-4HD Sidewall Power Venter CK-43 Control Kit Includes: 4" MG-1 Barometric Draft Control Fan Proving Switch Adjustable post purge For Use On The Following Lennox Series Furnaces: G24M...
  • Page 18 Under no circumstances can any standing pilot furnace be horizontally vented. Under no circumstances can any additional appliances be common vented with the furnace by the Field Controls SWG-4R. Under no circumstances can a furnace equipped with a natural draft diverter be horizontally vented.
  • Page 19 A single wall increaser will also be required at the furnaces with 3" outlet collars when 4" vent pipe is used. General Wiring For complete installation information refer to the Field Controls SWG-4R Power Venter Installation Manual for details (P/N 46331300.) SWG-4Y YORK SIDEWALL POWER VENTING KIT...
  • Page 20 80,000 4" None Required 100,000 4" None Required 120,000 4" None Required 140,000 4" None Required General Wiring For complete installation information refer to the Field Controls SWG-4Y Power Venter installation manual for details (P/N 46297600.) P/N 46334200 Page 20...