4. Select the control type according to your converter variant and make the necessary settings
for fail-safe digital inputs and the forced checking procedure (test stop):
Note
The illustration above takes a SINAMICS G115D PROFINET variant as an example. On AS-i
and I/O control variants, only the control type "via terminals" is available.
* Not available when selecting the control type "via terminals"
SINAMICS G120 Smart Access
Operating Instructions, 12/2020, A5E43332487-004
No.
Parameter
P9650
P9651
P9610 *
P60022 *
r9773.1
P9659
r9773.31
Description
Function
SI F-DI changeover
Tolerance time to change over the
discrepancy time
fail-safe digital input for the basic
(processor 1) [ms]
functions.
Factory setting: 500 ms
SI STO debounce time
Debounce time of the fail-safe digital
(processor 1) [ms]
input for the basic functions.
Factory setting: 1 ms
SI PROFIsafe address
Sets the PROFIsafe address for proces-
(processor 1)
sor 1.
PROFIsafe telegram
Sets the telegram number for PROFIs-
selection
afe.
CO/BO: SI status (pro-
Signals for the higher-level control
cessor 1 + processor
system.
2)
Bit 1: STO is active in the drive
SI forced checking
Monitoring time for the forced
procedure timer [h]
dormant error detection.
Factory setting: 8 h
CO/BO: SI status (pro-
Signals for the higher-level control
cessor 1 + processor
system.
2)
Bit 31: Test stop is required for STO
Standard Web pages
5.4 Quick setup
69