INPUT AND OUTPUT CABLES
Must use cables with the appropriate voltage and temperature ratings to ensure safe, reliable operation.
ACCESSORIES
Only accessories which meet the manufacturer's specifications shall be used. For identification and
instructions for connection of accessories, refer to the user manual.
HANDLING, LIFTING AND CARRYING
Handling, lifting and carrying of the equipment shall be made only according to the instructions specified
in the user manual to avoid potential personal injury.
DISCONNECT DEVICE
For GEN750W and GENH750W: The appliance coupler is the main disconnect device of the equipment
which reliably shuts off the supply from the equipment.
For GEN1500W: A circuit breaker with current ratings as specified in the user manual is the main disconnect
device of the equipment which reliably shuts off the supply from the equipment.
The positioning of the equipment must not make it difficult to operate the disconnect device.
NOTE: The switch incorporated in the equipment does NOT act as a main disconnect device and does not
cut the supply or power from the equipment. It is added as a means to shut down certain circuits inside
the power supply such as the display and the output circuit.
INSTALLATION
Installation of the equipment or the system incorporating the equipment must be in accordance with
the installation instructions provided by the manufacturer. The safety of any system incorporating the
equipment is the responsibility of the assembler.
IMPROPER USAGE OF THE EQUIPMENT
If the equipment is used in a manner not specified by the manufacturer, the protection provided by the
equipment may be impaired.
RACK MOUNTING SAFETY INSTRUCTIONS
A) Elevated Operating Ambient - If installed in a closed or multi-unit rack assembly, the operating ambient
temperature of the rack environment may be greater than room ambient. Therefore, consideration
should be given to installing the equipment in an environment compatible with the maximum ambient
temperature (Tma)specified by the manufacturer.
B) Reduced Air Flow - Installation of the equipment in a rack should be such that the amount of air flow
required for safe operation of the equipment is not compromised.
C) Mechanical Loading - Mounting of the equipment in the rack should be such that a hazardous condition
is not achieved due to uneven mechanical loading.
D) Circuit Overloading - Consideration should be given to the connection of the equipment to the supply
circuit and the effect that overloading of the circuits might have on overcurrent protection and supply
wiring. Appropriate consideration of equipment nameplate ratings should be used when addressing this
concern.
E) Reliable Earthing - Reliable earthing of rack-mounted equipment should be maintained. Particular attention
should be given to supply connections other than direct connections to the branch circuit (e.g. use of
power strips).
USERS
This equipment must be operated only by qualified personnel who understand the instructions and safety
manuals provided with the equipment. If the equipment must be operated by an unqualified personnel,
then he/she must be supervised by a qualified personnel.
Need help?
Do you have a question about the Genesys GENH Series and is the answer not in the manual?
Questions and answers