Settings And Optimum Operating Values - BÖWE P12 Instruction Manual

Hide thumbs Also See for P12:
Table of Contents

Advertisement

5. Settings and Optimum Operating Values

Machine
Basic value:
Steam pressure (saturated steam)
Steam temperature (max. permitted)
Cooling water pressure
Cooling water temperature, max.
Compressed air
Cage speeds:
Cleaning/
Spinning
Reversing cycle (cleaning)
Low level
High level
Pump pressure (max.)
Filter surface, economy filter
Filter powder (only for machines without emission-
free still rake out system)
Tank I: optimum filling volume (high level)
Tank III: optimum filling volume
Detergent solution cooler:
Detergent solution thermal sensor:
Detergent solution cooler ON
Refrigeration technology:
Filling capacity, cooling agent R 404A
Nozzle size:
solvent cooling
Drying + Reduction
High pressure control switch ON
High pressure control switch OFF
Low pressure control
Drying:
Cooling water regulator setting:
Adjust 4 – 6 min. after start of drying
Temp. sensor, cage entry (gentle drying)
Temp. sensor, cage exit
Temp. sensor after cooler:
Control value, drying
Control value, cycle end
Safety thermostat, heater battery (elec. only)
21
bar(psi)
°C(°F)
bar(psi)
°C(°F)
bar(psi)
RPM
RPM
sec.
l(US gal)
l(US gal)
bar(psi)
2
2
m
(ft
)
kg(lb)
l(US gal)
l(US gal)
°C(°F)
kg(lb)
no.
no.
approx.
bar(psi)
approx.
bar(psi)
approx.
bar(psi)
bar(psi)
°C(°F)
°C(°F)
°C(°F)
°C(°F)
°C(°F)
P12
4–5(58–72.5)
4–5(58 – 72.5)
150(302)
150(302)
2-4(29-58)
2-4(29-58)
25(77)
6(87)
35
500
10/1/10
30(7.9)
60(15.8)
2.5(36.2)
2.5(36.2)
2.7(29.0)
2.7(29.0)
1.2(2.6)
60(15.8)
60(15.8)
15–30(59-86)
15 – 30(59-86)
4.6(10.1)
4.6(10.1)
03
06
21(319)
26(377)
1(14.5)
20(290)
60(140)
50(122)
40(104)
15(59)
110(230)
110(230)
P12 /P15 /P18
P15
25(77)
6(87)
35
500
10/1/10
35(9.2)
70(18.5)
1.2(2.6)
75(19.8)
75(19.8)
03
06
21(319)
26(377)
1(14.5)
20(290)
60(140)
50(122)
40(104)
15(59)

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

P15P18P21P26P30

Table of Contents